首页 | 本学科首页   官方微博 | 高级检索  
     


Between-day reliability of triceps surae responses to standing perturbations in people post-stroke and healthy controls: A high-density surface EMG investigation
Affiliation:1. PhD Student, Université du Québec à Trois-Rivières, Département d’anatomie, Trois-Rivières, Quebec, Canada;2. Postdoctoral Fellowship, Université du Québec à Trois-Rivières, Département des sciences de l’activité physique, Trois-Rivières, Quebec, Canada;3. Chiropractic Student, Université du Québec à Trois-Rivières, Département de chiropratique, Trois-Rivières, Quebec, Canada;4. Full Professor, Université du Québec à Trois-Rivières, Département des sciences de l’activité physique, Trois-Rivières, Quebec, Canada;1. Professor, Iranian Research Centre on Aging, Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Evin, Tehran, Iran;2. Visiting Professor, University Institute of Physical Therapy, Faculty of Allied Health Sciences, University of Lahore, Lahore, Pakistan;3. PhD Student, Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;4. Assistant Professor, Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;5. Assistant Professor, Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;6. PhD Student, Department of Physiotherapy, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran;7. Assistant Professor, Department of Physical Therapy, University Institute of Physical Therapy, University of Lahore, Lahore, Pakistan
Abstract:
The reliability of triceps surae electromyographic responses to standing perturbations in people after stroke and healthy controls is unknown. High-Density surface Electromyography (HDsEMG) is a technique that records electromyographic signals from different locations over a muscle, overcoming limitations of traditional surface EMG such as between-day differences in electrode placement. In this study, HDsEMG was used to measure responses from soleus (SOL, 18 channels) and medial and lateral gastrocnemius (MG and LG, 16 channels each) in 10 people after stroke and 10 controls. Timing and amplitude of the response were estimated for each channel of the grids. Intraclass Correlation Coefficient (ICC) and normalized Standard Error of Measurement (SEM%) were calculated for each channel individually (single-channel configuration) and on the median of each grid (all-channels configuration). Both timing (single-channel: ICC = 0.75–0.96, SEM% = 5.0–9.1; all-channels: ICC = 0.85–0.97; SEM% = 3.5–6.2%) and amplitude (single-channel: ICC = 0.60–0.91, SEM% = 25.1–46.6; ICC = 0.73–0.95, SEM% = 19.3–42.1) showed good-to-excellent reliability. HDsEMG provides reliable estimates of EMG responses to perturbations both in individuals after stroke and in healthy controls; reliability was marginally better for the all-channels compared to the single-channel configuration.
Keywords:Reliability  Stroke  Perturbation  Posture  High-density surface electromyography
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号