首页 | 本学科首页   官方微博 | 高级检索  
检索        

正常人和脑梗死患者颈动脉血流超声多普勒时频分析
引用本文:钱国正,李友发,曹奕丰.正常人和脑梗死患者颈动脉血流超声多普勒时频分析[J].第二军医大学学报,2001,22(12):1178-1180.
作者姓名:钱国正  李友发  曹奕丰
作者单位:第二军医大学长海医院生物医学工程研究室,
基金项目:上海市科技发展基金资助项目 (No.984 4 190 14 )
摘    要:目的:分别对正常人和脑梗死患颈动脉血流超声多普勒时频分析,为临床应用提供参考资料。方法:检测正常人和脑梗患(大多有颈动脉粥样硬化斑块)的颈动脉多普勒血流时频谱,以其峰值频率(fmax),模式频率(fmode),平均频率(fmean),低值频率(fmin),重脉波频率(fp)和频弥散宽度(fw)为定量指标。结果:正常人颈动脉血流信号时频谱的fmax,fmean和fmode曲线在一个心动周期中具有总体相似的形状,相互嵌套,其中收缩期的fmax最高,均大于3kHz,fmin最低不低于1kHz,脑梗死患颈动脉时频谱的fmax与fmean和fmode两曲线分开,fmax减低(<3kHz),fp消失,舒张末期fmin减低显(均低于0.5kHz),结论:颈动脉多普勒血流时频分析及所遴选的定量指标对颈动脉粥样硬化斑块十分敏感,可供诊断试验,且可集成在便携式计算机里,适用于社区人群中筛选易中风病变个体。

关 键 词:脑梗死  颈动脉  超声波检查  时频分析  劲动脉血流
文章编号:0258-879X(2001)12-1178-03
修稿时间:2001年4月21日

Time-frequence analysis of carotid flow doppler signal in normal controls and cerebral infarction patients
QIAN Guo Zheng,LI You Fa,CAO Yi Feng.Time-frequence analysis of carotid flow doppler signal in normal controls and cerebral infarction patients[J].Academic Journal of Second Military Medical University,2001,22(12):1178-1180.
Authors:QIAN Guo Zheng  LI You Fa  CAO Yi Feng
Abstract:Objective: To analyze time frequence of carotid flow Doppler signal of normal and cerebral infarction cases, providing reference for clinical applications. Methods: Time frequence spectrums of carotid flow Doppler signal of normal persons and of cerebral infarction cases (mostly with carotid atheromatous plaque) were detected. The peak frequence or envelope ( f max ), the mode frequence or the frequence with the greatest power ( f mode ), the mean frequence ( f mean ), the lowest frequence or the mean frequence in end diastolic phase ( f min ), duplicate pulse frequence or the frequence at the second duplicate peak ( f p) and spectral width or the time width at the half of the peak frequence ( f w) were taken as quantity indexes. Results: For normal persons, the frequence plots was a general uniformity of the shape of the frequence envelope throughout the cardiac cycle with similar values, f max in systole >3 kHz and f min > 1 kHz at least; For the cerebral infarction cases with carotid atheromatous plaque, the frequence plots for f max , f mode and f mean were separated throughout the cardiac cycle, f max in systole <3 kHz, duplicate pulse frequence disappeared and, as a significant feature, f min <0.5 kHz for every case. Conclusion: Time frequence analysis of carotid flow Doppler signal and quantity indexes selected by us are highly sensitive to abnormal cases with carotid atherosclerosis plaque and can be used as a diagnostic test. In addition, because these methods can be easily assembled in a notebook computer, they are especially suitable for screening individuals with the risk of stroke from the large population in communities.
Keywords:cerebral infarction  carotid arteries  ultrasonography  time  frequence analysis
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《第二军医大学学报》浏览原始摘要信息
点击此处可从《第二军医大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏