Carotid artery stenting in high surgical risk patients using the FiberNet® embolic protection system: The EPIC trial results |
| |
Authors: | Subbarao Myla MD FACC J. Michael Bacharach MD MPH FACC Gary M. Ansel MD FACC Eric J. Dippel MD FACC Daniel J. McCormick DO FACC Jeffrey J. Popma MD FACC |
| |
Affiliation: | 1. Hoag Memorial Hospital, Newport Beach, California;2. Department of Vascular Medicine, North Central Heart Hospital of South Dakota, Sioux Falls, South Dakota;3. Department of Cardiology, Riverside Methodist Hospital, Columbus, Ohio;4. Department of Cardiology, Trinity Terrace Park Medical Center, Bettendorf, Iowa;5. Department of Cardiology, Hahnemann University Hospital, Philadelphia, Pennsylvania;6. Department of Cardiology, Brigham and Women's Hospital, Boston, Massachusetts |
| |
Abstract: | Objective: The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single‐arm trial evaluated the 30‐day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Background: Embolic protection filters available for use during CAS include fixed and over‐the‐wire systems that rely on embolic material capture within a “basket” structure. The FiberNet® Embolic Protection System (EPS), which features a very low crossing profile, consists of a three‐dimensional fiber‐based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. Methods: The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30‐day follow‐up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. Results: The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30‐day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. Conclusions: The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30‐day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). © 2009 Wiley‐Liss, Inc. |
| |
Keywords: | PVD carotid stenting distal protection |
|
|