首页 | 本学科首页   官方微博 | 高级检索  
     


The fraction of inspired oxygen in infants receiving oxygen via nasal cannula often exceeds safe levels
Authors:Kuluz J W  McLaughlin G E  Gelman B  Cantwell G P  Thomas J  Mahon T  Schleien C L
Affiliation:Division of Critical Care Medicine, Department of Pediatrics, University of Miami School of Medicine/Jackson Memorial Hospital, Miami, Florida 33101-6960, USA. jkuluz@med.miami.edu
Abstract:OBJECTIVE: Measure the fraction of inspired oxygen (F(IO(2))) in infants receiving supplemental oxygen via nasal cannula and identify clinical variables that affect F(IO(2)). METHODS: Hypopharyngeal gas samples were obtained from 20 infants receiving oxygen via nasal cannula at flows between 0 and 4 L/min. F(IO(2)) was calculated using the alveolar gas equation and measurements of partial pressure of oxygen in the samples and the barometric pressure. RESULTS: F(IO(2)) increased as oxygen flow was increased. F(IO(2)) exceeded safe levels (> 60%) in two thirds of samples when the oxygen flow was 2 L/min or higher. Tachypnea (respiratory rate > 40 breaths/min) was associated with lower F(IO(2)). CONCLUSION: Infants receiving oxygen via nasal cannula at > or = 2 L/min may be at risk for hyperoxic lung injury. Therefore, we recommend using the lowest possible oxygen flow needed to maintain normoxia in infants requiring prolonged oxygen therapy via nasal cannula.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号