不同过滤方法对盐酸乙胺丁醇片含量测定的影响 |
| |
引用本文: | 刘君康,郭拓云,阿依古丽.不同过滤方法对盐酸乙胺丁醇片含量测定的影响[J].中国药品标准,2003,4(4):46-47. |
| |
作者姓名: | 刘君康 郭拓云 阿依古丽 |
| |
作者单位: | 新疆维吾尔自治区药品检验所,乌鲁木齐,830002 |
| |
摘 要: | 目的:探讨盐酸乙胺丁醇片含量测定中使用不同过滤方法对测定结果的影响。方法:采用全玻璃砂芯滤器过滤可排除滤纸对主药的吸附。结果:方法平均回收率为99.0%,RSD为0.17%。结论:本法准确,可靠。
|
关 键 词: | 过滤方法 盐酸乙胺丁醇片 含量测定 全玻璃砂芯滤器 滤纸 |
Effect of different filtered method on determination for ethambutol hydrochloride tablets |
| |
Authors: | Liu Junkang GuO Tuoyun and Ayiguli |
| |
Institution: | Xinjiang Provincial Institute for Drug Control, Urumqi, 830002;Xinjiang Provincial Institute for Drug Control, Urumqi, 830002;Xinjiang Provincial Institute for Drug Control, Urumqi, 830002 |
| |
Abstract: | Objective: The method of different filtered for content determination of Ethambutol Hydrochloride Tablets was studied. Method: Using glass filter may eliminate the influence of absorbing main ingredients when Ethambutol Hydrochloride Tablets are detemined. ResultS:The average recovery was 99- 0%,and RSD was 0. 17%. Conclusion: The method is accruate and trustiness. |
| |
Keywords: | different filtered method Ethambutol Hydrochloride Tablets content determination |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
| 点击此处可从《中国药品标准》浏览原始摘要信息 |
| 点击此处可从《中国药品标准》下载免费的PDF全文 |