首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of pulse wave velocity in the thoracic aorta by flow-sensitive four-dimensional MRI: reproducibility and correlation with characteristics in patients with aortic atherosclerosis
Authors:Markl Michael  Wallis Wolf  Strecker Christoph  Gladstone Beryl Primrose  Vach Werner  Harloff Andreas
Affiliation:Department of Radiology, Medical Physics, University Medical Center Freiburg, Germany. mmarkl@northwestern.edu
Abstract:

Purpose:

To measure aortic pulse wave velocity (PWV) using flow‐sensitive four‐dimensional (4D) MRI and to evaluate test–retest reliability, inter‐ and intra‐observer variability in volunteers and correlation with characteristics in patients with aortic atherosclerosis.

Materials and Methods:

Flow‐sensitive 4D MRI was performed in 12 volunteers (24 ± 3 years) and 86 acute stroke patients (68 ± 9 years) with aortic atherosclerosis. Retrospectively positioned 28 ± 4 analysis planes along the entire aorta (inter‐slice‐distance = 10 mm) and frame wise lumen segmentation yielded flow‐time‐curves for each plane. Global aortic PWV was calculated from time‐shifts and distances between the upslope portions of all available flow‐time curves.

Results:

Inter‐ and intra‐observer variability of PWV measurements in volunteers (7% and 8%) was low while test–retest reliability (22%) was moderate. PWV in patients was significantly higher compared with volunteers (5.8 ± 2.9 versus 3.8 ± 0.8 m/s; P = 0.02). Among 17 patient characteristics considered, statistical analysis revealed significant (P < 0.05) but low correlation of PWV with age (r = 0.25), aortic valve insufficiency (r = 0.29), and pulse pressure (r = 0.28). Multivariate modeling indicated that aortic valve insufficiency and elevated pulse pressure were significantly associated with higher PWV (adjusted R2 = 0.13).

Conclusion:

Flow‐sensitive 4D MRI allows for estimating aortic PWV with low observer dependence and moderate test–retest reliability. PWV in patients correlated with age, aortic valve insufficiency, and pulse pressure. J. Magn. Reson. Imaging 2012;35:1162‐1168. © 2012 Wiley Periodicals, Inc.
Keywords:flow‐sensitive 4D MRI  blood flow  pulse wave velocity  aorta  phase contrast
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏