首页 | 本学科首页   官方微博 | 高级检索  
检索        

不同体位固定方式在乳腺癌放疗中的应用
引用本文:高瀚,钱普东,明学中,江宁,王凤仪,郭昌,许俊,孙丽.不同体位固定方式在乳腺癌放疗中的应用[J].中华放射医学与防护杂志,2022,42(1):12-17.
作者姓名:高瀚  钱普东  明学中  江宁  王凤仪  郭昌  许俊  孙丽
作者单位:江苏省肿瘤医院 江苏省肿瘤防治研究所 南京医科大学附属肿瘤医院放疗科, 南京 210009
基金项目:江苏省卫健委干部保健课题(BJ19031)
摘    要:目的:研究真空垫(VP)、真空垫联合乳腺托架(VB)和发泡胶联合乳腺托架(PB)对乳腺癌放疗中分次间摆位误差、分次内患者移动及剂量学的影响。方法:前瞻性收集2019-2021年在江苏省肿瘤医院接受放射治疗乳腺癌患者共96例,按简单随机法分为VP组、VB组和PB组,每组32例。利用锥形束CT(CBCT)和计划系统获取患者...

关 键 词:真空垫  发泡胶  乳腺托架  乳腺肿瘤  放射治疗
收稿时间:2021/9/27 0:00:00

Application of different posture fixation methods in radiotherapy of breast cancer
Gao Han,Qian Pudong,Ming Xuezhong,Jiang Ning,Wang Fengyi,Guo Chang,Xu Jun,Sun Li.Application of different posture fixation methods in radiotherapy of breast cancer[J].Chinese Journal of Radiological Medicine and Protection,2022,42(1):12-17.
Authors:Gao Han  Qian Pudong  Ming Xuezhong  Jiang Ning  Wang Fengyi  Guo Chang  Xu Jun  Sun Li
Institution:Department of Radiation Oncology, Jiangsu Cancer Hospital, Jiangsu Institute of Cancer Research, Affiliated Cancer Hospital of Nanjing Medical University, Nanjing 210009, China
Abstract:Objective To study the inter-fraction setup errors, intra-fraction movement of patients and its influence on dosimetry, position repeatability of the supraclavicular area, and the plastic stability of the vacuum cushion and styrofoam when one of the three fixation method are applied in the clinical radiotherapy of breast cancer. The three fixation method include acuum negative pressure pad (VP), acuum negative pressure pad combined with a breast bracket (VB), and polyurethane styrofoam combined with a breast bracket (PB).Methods A total of 96 breast cancer patients who received radiotherapy at Jiangsu Cancer Hospital during 2019-2021 were collected prospectively for study. They were randomly divided into three groups (VP, VB, and PB). Cone-Beam CT and a planning system were used to obtain inter-fraction setup errors, intra-fraction movement of patients and its influence on dosimetry, position repeatability of supraclavicular area, and the plastic stability of vacuum pad and polyurethane tyrofoam.Results In the left-right (LR) direction, there were no statistical differences in the inter-fraction setup errors among the three groups. In the superior-inferior (SI) direction, inter-fraction setup errors of the PB group were smaller than those of the VB group (3.02 ±2.04, 3.65 ±2.64, t=2.35, P=0.031). In the anterior-posterior (AP) direction, the inter-fraction setup errors of both the VB and PB groups were smaller than those of the VP group (3.36 ±2.93, 3.14 ±0.98, 4.03 ±2.55, t=2.29, 3.11, P < 0.05). In the AP direction, the intra-fraction movement of patients of the VP and PB groups were less than that of the VB group (1.31 ±0.95, 1.24 ±0.89, 1.88 ±1.33, t=-2.04, -2.31, P < 0.05). Moreover, the intra-fraction movement of patients had no statistical effect on the dosimetric distribution (P> 0.05), and the breast bracket did not improve the position repeatability of the supraclavicular region (P>0.05). In addition, the plastic stability of polyurethane styrofoam was significantly better than that of the acuum negative pressure pad (t=2.43-5.63, P < 0.05).Conclusions The inter-fraction setup errors and intra-fraction movement of patients with breast cancer can be reduced by using PB. Compared to an acuum negative pressure pad, polyurethane styrofoam can keep plastic stability throughout the treatment of the patients.
Keywords:Acuum negative pressure pad  Polyurethane styrofoam  Breast bracket  Breast cancer  Radiotherapy
本文献已被 维普 等数据库收录!
点击此处可从《中华放射医学与防护杂志》浏览原始摘要信息
点击此处可从《中华放射医学与防护杂志》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号