首页 | 本学科首页   官方微博 | 高级检索  
     

锥形束CT在下颌阻生第三磨牙拔除术前诊断应用的初步研究
引用本文:Chen Q,Zhang X,Zhang G,Ma XC. 锥形束CT在下颌阻生第三磨牙拔除术前诊断应用的初步研究[J]. 中华口腔医学杂志, 2011, 46(7): 398-402. DOI: 10.3760/cma.j.issn.1002-0098.2011.07.004
作者姓名:Chen Q  Zhang X  Zhang G  Ma XC
作者单位:1. 北京大学口腔医学院·口腔医院第一门诊部,100034
2. 北京大学口腔医学院·口腔医院放射科,100034
摘    要:目的 评价口腔颌面锥形束CT(cone beam CT,CBCT)确定下颌阻生第三磨牙(impacted mandibular third molar,IMTM)与下牙槽神经管位置关系,为IMTM拔除术中预防下牙槽神经损伤提供临床依据.方法 通过IMTM拔除术前曲面体层X线片检查,筛选出IMTM与下牙槽神经管存在较大范围接触或部分重叠影像表现的49例患者(60侧),进一步行CBCT检查,结合种植机微动力系统微创拔牙术中观察结果,应用诊断试验的方法评价术前CBCT检查结果的准确性.结果 术前CBCT观察IMTM突破下牙槽神经管壁判断的灵敏度82.8%、特异度87.0%,Youden指数0.69,阳性预测值88.9%,阴性预测值80.0%.两位口腔放射医师术前对CBCT共同判读的结果与术中观察结果的符合率为84.6%(44/52).对两位医师术前分别判读CBCT影像的结果进行一致性分析,Kappa值=0.80.结论 对于曲面体层X线片显示IMTM与下牙槽神经管存在较大范围接触或部分重叠影像表现的病例应用CBCT术前检查,CBCT显示的IMTM与下牙槽神经管的关系与临床实际观察结果一致性较高.
Abstract:
Objective To evaluate the diagnostic accuracy of the cone beam computed tomography(CBCT)in judging the relationship between the impacted mandibular third molar(IMTM)and the inferior alveolar canal(IAC).Methods Sixty IMTM superimposing on the canal partially or touching the canal in line on panoramic radiograms were examined by CBCT. All CBCT images of these cases were observed by two dentists respectively. Then, all these IMTM were extracted by minimally invasive surgery, and the conditions of the IMTM sockets were observed. Two dentists observed the CBCT images independently and reached a consensus. Diagnosis test was performed in this study. Results Eight IMTM sockets were bleeding during the extracted operation, and whether the IAC wall was broken could not be judged. The other 52 IMTM sockets were clear and the walls of IAC were broken in 29 IMTM extractions. The sensitivity, specificity, Youden index, positive predictive value and negative predictive value of CBCT were 82.8%, 87.0%, 88.9% and 80.0% respectively. The diagnostic accuracy judged by the two dentists and Kappa coefficient were calculated as 84.6% and 0.800. Conclusions The CBCT examination had good authenticity and reliability, and it was very helpful in predicting the actual relationship between the IMTM and IAC.

关 键 词:牙,阻生  曲面体层摄影术  锥形束CT

Pilot clinical study of the dental cone beam CT examination before the impacted mandibular third molar extraction
Chen Quan,Zhang Xiao,Zhang Gang,Ma Xu-chen. Pilot clinical study of the dental cone beam CT examination before the impacted mandibular third molar extraction[J]. Chinese journal of stomatology, 2011, 46(7): 398-402. DOI: 10.3760/cma.j.issn.1002-0098.2011.07.004
Authors:Chen Quan  Zhang Xiao  Zhang Gang  Ma Xu-chen
Affiliation:The First Outpatient Dental Clinic, Peking University School and Hospital of Stomatology, Beijing, China.
Abstract:Objective To evaluate the diagnostic accuracy of the cone beam computed tomography(CBCT)in judging the relationship between the impacted mandibular third molar(IMTM)and the inferior alveolar canal(IAC).Methods Sixty IMTM superimposing on the canal partially or touching the canal in line on panoramic radiograms were examined by CBCT. All CBCT images of these cases were observed by two dentists respectively. Then, all these IMTM were extracted by minimally invasive surgery, and the conditions of the IMTM sockets were observed. Two dentists observed the CBCT images independently and reached a consensus. Diagnosis test was performed in this study. Results Eight IMTM sockets were bleeding during the extracted operation, and whether the IAC wall was broken could not be judged. The other 52 IMTM sockets were clear and the walls of IAC were broken in 29 IMTM extractions. The sensitivity, specificity, Youden index, positive predictive value and negative predictive value of CBCT were 82.8%, 87.0%, 88.9% and 80.0% respectively. The diagnostic accuracy judged by the two dentists and Kappa coefficient were calculated as 84.6% and 0.800. Conclusions The CBCT examination had good authenticity and reliability, and it was very helpful in predicting the actual relationship between the IMTM and IAC.
Keywords:Tooth,impactd  Orthopantomography  Cone beam computed tomography
本文献已被 万方数据 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号