Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms |
| |
Authors: | Eduardo Wajnberg MD Jorge Marcondes de Souza MD PhD Edson Marchiori MD PhD Emerson L. Gasparetto MD PhD |
| |
Affiliation: | aDepartment of Radiology and Interventional Radiology, University of Brazil, 21941-913 Rio de Janeiro RJ, Brazil;bDepartment of Neurosurgery, University of Brazil, 21941-913 Rio de Janeiro RJ, Brazil |
| |
Abstract: | BackgroundStent-assisted coiling is an accepted endovascular treatment (EVT) for wide-necked intracranial aneurysms. The Neuroform stent (Target Therapeutics, Fremont, Calif) is a flexible nitinol self-expandable stent that was designed to potentially overcome the limitations of balloon expandable coronary stents in the intracranial circulation. The aim of this study was to reenforce the use of this stent for EVT of wide-necked cerebral aneurysms.MethodsBetween March 2005 and March 2008, 24 patients harboring wide-necked cerebral aneurysms were treated with stent reconstruction of the aneurysm neck. Inclusion criteria restricted the group to adult patients with wide-necked intracranial aneurysms (ruptured and unruptured lesions). Immediate postprocedure angiography studies were performed to determine successful coil occlusion of the aneurysm as well as patency of the parent vessel. We assessed the clinical history, aneurysm dimensions, and technical detail of the procedures, including any difficulties with stent placement and deployment, degree of aneurysm occlusion, and complications. Clinical outcome was assessed with the Glasgow Outcome Scale (GOS).ResultsThe stent was easily navigated and precisely positioned in 24 of 26 cases. However, technical difficulties occurred in 9 patients, including difficulties in crossing the stents interstice in 6 cases, inadvertent stent delivery (n = 1), and incapacity of stent delivery (n = 1) and incapacity of crossing the neck (n = 1). These latter 2 cases were classified as failures of the stent-assisted technique. A single procedural complication occurred, involving transient nonocclusive intrastent thrombus formation, which was treated uneventfully with abciximab. Seventeen patients experienced excellent clinical outcomes (GOS 5), with good outcomes (GOS 4) in 5 patients and a poor outcome (GOS 3) in 2 patients. There were no treatment-related deaths or neurologic complications (mean clinical follow-up, 12 months). Angiographic results consisted of 17 complete occlusions, 4 neck remnants, and 3 incomplete occlusions.ConclusionsThe Neuroform stent is very useful for EVT of wide-necked intracranial aneurysms because it is easy to navigate and to deploy accurately. In most cases, the stent can be deployed precisely, even in very tortuous carotid siphons. Although in some cases delivery and deployment was challenging, clinically significant complications were not observed. |
| |
Keywords: | Abbreviations: ACom, Anterior Communicating artery AVM, Arteriovenous Malformation CT, Computed tomography DNA, Desoxiribonucleic Acid EVT, Endovascular treatment GDC, Guglielmi detachable coils GOS, Glasgow Outcome Scale IDA, Incidentally diagnosed aneurysm ISUIA, International Study of Unruptured intracranial aneurysms MCA, Middle cerebral artery MRI, Magnetic resonance imaging PCom, Posterior Communicationg Artery PICA, Posterior inferior cerebellar artery SAH, Subarachnoid hemorrhage |
本文献已被 ScienceDirect 等数据库收录! |
|