Parathyroid adenomas evaluated by Tl-201/Tc-99m pertechnetate subtraction scintigraphy and high-resolution ultrasonography
Authors:Winzelberg, GG   Hydovitz, JD   O'Hara, KR   Anderson, KM   Turbiner, E   Danowski, TS   Lippe, RD   Melada, GA   Harrison, AM
Abstract:Thallium-201/technetium-99m pertechnetate subtraction scintigraphy of the parathyroid glands was performed in a prospective study of 33 patients who had undergone bilateral neck exploration for elevated serum calcium and serum parathyroid hormone levels. In 31 cases, the Tl-201/Tc-99m subtraction technique yielded an overall sensitivity of 81%, specificity of 99%, and accuracy of 94% for identifying solitary parathyroid adenomas. Tl-201/Tc-99m subtraction scintigraphy correctly identified 73% of parathyroid adenomas weighing less than 499 mg, 79% of those weighing 500-1,499 mg, and 100% of adenomas weighing more than 1,500 mg. In a subgroup of 24 patients with solitary parathyroid adenomas who underwent both scintigraphy and high-resolution sonography, the sensitivity, specificity, and accuracy of both procedures were similar.