Autotransfusion after open heart surgery: the oxygen delivery capacity of shed mediastinal blood is maintained
Authors:H Schmidt    U Kongsgaard    J Kofstad    O Geiran  H E Refsum
Institution:Department of Anaesthesia, Rikshospitalet, Oslo, Norway;Department of Clinical Chemistry, Rikshospitalet, Oslo, Norway;Department of Surgery, Rikshospitalet, Oslo, Norway;Department of Anaesthesia, the Norwegian Radium Hospital, Oslo, Norway;Institute for Respiratory Physiology, Ullevål Hospital, Oslo, Norway
Abstract:Autotransfusion of mediastinal shed blood after open heart surgery has become a common and accepted procedure in reducing the need for homologous transfusion during the last 15 years. The objectives of the present study were to investigate the oxygen delivery capacity of autotransfused shed mediastinal blood, compared to patient-blood, during cardiopulmonary bypass and in the postoperative period.
Ten consecutive patients undergoing elective cardiac surgery were studied. Mediastinal shed blood was collected in the cardiotomy reservoir and retransfused during the first 18 postoperative hours. The oxygen delivery capacity of the blood to the tissues was calculated by use of the oxygen status algorithm (OSA 2.0) programme and measurement of the 2,3-diphosphoglycerate (2,3-DPG) concentration.
Autotransfusion volume ranged from 450–1530 ml per patient (median 824 ml). Shed blood had a mean haemoglobin level of 8.8 g/dl and 7.4 g/dl at 1 h and 6 h of autotransfusion, respectively. There were no significant changes of 2,3-DPG concentration in the patient-blood during cardiopulmonary bypass or after autotransfusion compared to preoperative values. P50 for oxygen (3.6 and 3.6 kPa) and 2,3-DPG concentrations (5.3 and 5.1 mikromol/ml erythrocyte) in shed mediastinal blood (1h and 6h postoperatively) were not significantly different compared to patient-blood.
The results demonstrate that the oxygen delivery capacity of shed mediastinal blood is maintained and that the oxygen affinity of patient-blood is not influenced by autotransfusion.
Keywords:Autotransfusion  cardiac surgery  oxygen  p50 for oxygen  2  3-diphosphoglycerate