Tunica media of aorta and pulmonary trunk in relation to internal calibres in transposition of great arteries,in aortic and pulmonary atresia and in normal hearts |
| |
Authors: | Dr Hilde van Meurs-van Woezik Hans Werner Klein Piet Krediet |
| |
Institution: | (1) Faculty of Medicine, Dept. of Anatomy HB 12, Erasmus University, P.O. Box 1738, 3000 DR Rotterdam, The Netherlands |
| |
Abstract: | Summary In a post mortem material of 17 cases of transposition of the great arteries (TGA) from patients with an age range from birth to two years and ten months after birth, the internal calibres of the great arteries and the ostia of the heart proved to be the same as in normal hearts. Furthermore, the media of the ascending aorta and pulmonary trunk showed no adaptation to the abnormal circulatory conditions in 15 cases of TGA with an age range from birth up to 51/2 months: in both great arteries the thickness of the tunica media and the packing density of its elastic fibres were the same as in normal hearts. However, adaptation of the tunica media of the pulmonary trunk to the abnormal circulatory conditions: increased media thickness, was found in the two remaining cases, older than 12 months.In 7 cases of pulmonary atresia (age from 1 day to 12 months) and in 9 cases of aortic atresia (age from 2 days to 37 days) the following observations were made. Vessels with reduced or absent function (ascending aorta in aortic atresia and pulmonary trunk in pulmonary atresia) showed a markedly different structure. In aortic atresia the internal calibre and thickness of the media of the ascending aorta were markedly reduced, whereas the packing density of the elastic fibres of the media remained the same as in normal hearts. In pulmonary atresia the pulmonary trunk showed large variations in internal calibre, whereas both media thickness and the packing density of its elastic fibres remained the same as in normal hearts. When the markedly enlarged single functional vessels (the pulmonary trunk in aortic atresia and the ascending aorta in pulmonary atresia) were compared no significant differences between their internal calibre, media thickness and the packing density of the elastic fibres were found indicating similar adaptation to the abnormal but comparable functional load of acting as sole arterial trunk.We are indebted to Prof. Dr. J. Moll for his help, to Dr. J.J. Willemse for statistical calculations, to Mr. P. Zondervan, M.D. (Dept. of Pathology I), for supply of material and to Mrs. L. Silvis for histo-technical assistance |
| |
Keywords: | Media Calibres Aorta Pulmonary trunk |
本文献已被 SpringerLink 等数据库收录! |
|