首页 | 本学科首页   官方微博 | 高级检索  
     


Influence of recording site withing the muscle on motor unit potentials
Authors:Bj  rn Falck,Erik St  lberg,Christian Bischoff
Affiliation:Björn Falck,Erik Stålberg,Christian Bischoff
Abstract:The influence of the recording site on the motor unit potentials (MUPs) was investigated in the brachial biceps muscle of 8 healthy subjects. The MUPs were recorded with a concentric needle electrode and analyzed with a new decomposition EMG program we call multi-MUP analysis. MUPs had shorter durations and smaller amplitudes at superficial recording sites than at deeper sites in the muscle. This is mainly due to the cannula of the concentric electrode, which records a higher potential at superficial recording sites and partially cancels the recorded potentials from the tip in a differential recording. The MUPs had longer durations and higher amplitudes distally than in the middle of the muscle. The longer durations and spike durations are probably due to increased temporal dispersion at a greater distance from the endplate zone. We do not have an adequate explanation for the larger amplitudes distally in the biceps, they may be due to anatomical factors. To increase the diagnostic sensitivity of quantitative MUP analysis the recordings should be obtained from standardized recording sites. © 1995 John Wiley & Sons, Inc.
Keywords:decomposition EMG  quantitative EMG  motor unit potential  reference values  recording position
设为首页 | 免责声明 | 关于勤云 | 加入收藏