Stent-in-stent through a side hole to prevent biliary metallicstent migration |
| |
Authors: | Ridtitid Wiriyaporn Rerknimitr Rungsun Amornsawadwattana Surachai Ponauthai Yuwadee Kullavanijaya Pinit |
| |
Affiliation: | Wiriyaporn Ridtitid, Rungsun Rerknimitr, Surachai Amornsawadwattana, Yuwadee Ponauthai, Pinit Kullavanijaya, Division of Gastroenterology, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand |
| |
Abstract: | The covered self-expandable metallic stent (SEMS) has been developed to overcome the problem of tissue in-growth, However, stent migration is a well-known com--plication of covered SEMS placement. Use of a double pigtail stent to lock the movement of the SEMS and prevent migration has been advised by many ex-perts. Unfortunately, in our case this technique led to an in-cidental upward migration of the SEMS. We used APC to create a side hole in the SEMS for plastic stent insertion as stent-in-stent. This led to a successful pre-ven-tion of stent migration. |
| |
Keywords: | Metallic stent migration Distal biliary obstruction |
本文献已被 CNKI PubMed 等数据库收录! |
|