首页 | 本学科首页   官方微博 | 高级检索  
     

双钢板垂直和平行放置治疗C型肱骨远端骨折的对比研究
引用本文:蓝霞,张立海,陶笙,张群,梁向党,袁邦拓,徐文鹏,尹鹏,唐佩福. 双钢板垂直和平行放置治疗C型肱骨远端骨折的对比研究[J]. 中华医学杂志(英文版), 2013, 126(12): 2337-2342
作者姓名:蓝霞  张立海  陶笙  张群  梁向党  袁邦拓  徐文鹏  尹鹏  唐佩福
作者单位:The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army,The General Hospital of the People’s Liberation Army
基金项目:This,research,was,supported,by,a,grant,from,the,National,Developing,Plan,of,High,Technique(项目编号:SS2012AA041604)
摘    要:
Background Double plate osteosynthesis is the standard treatment for intra-articular fractures of the distal humerus. However, there is still controversy concerning dual plate positions in terms of providing optimal stability. The purpose of this retrospective study was to compare the clinical outcomes in patients with type C intra-articular distal humeral fractures using perpendicular and parallel plating methods.
Methods Between March 2008 and June 2011, a total of 45 patients with type C distal humerus fractures were treated using two different dual plating methods. Of them, 24 patients were treated by perpendicular plating (group I) and 21 patients were treated by parallel plating (group II). The surgical time, blood loss, and union time were compared between the two groups. The flexion-extension arc, the total range of flexion and extension at the end of follow-up were compared between the two groups. The Mayo Elbow Performance Score (MEPS) was used to determine the elbow functional results.
Results All patients were followed up. The mean duration of follow-up was 16 months (range 12–25 months) in group I and 15.5 months in group II (range 12–25 months). There were no significant differences in the surgical time, blood loss, and the bone union time between the two groups. In group I, the mean elbow flexion-extension arc was 101° and the mean MEPS was 85 points. The rate of excellent and good results was 87.5%. In group II, the mean flexion-extension arc was 100° and the mean MEPS was 86.1 points. The rate of excellent and good results was 90.5%. There were no significant differences in the MEPS, flexion-extension arc, and the total range of flexion and extension between the two groups.
Conclusions Perpendicular and parallel plate configurations with the appropriate surgical techniques can provide anatomical reconstruction and stable fixation of type C intra-articular distal humeral fractures and allow early mobilization of the elbow after an operation. The occurrence of post-operative elbow stiffness can be reduced and good outcomes can be obtained.


关 键 词:骨折愈合  平行板  远端  肱骨  C型  垂直  手术方法  电镀方法

Comparative study of perpendicular versus parallel double plating methods for type C distal humeral fractures
LAN Xi,ZHANG Li-hai,TAO Sheng,ZHANG Qun,LIANG Xiang-dang,YUAN Bang-tuo,XU Wen-peng,YIN Peng and TANG Pei-fu. Comparative study of perpendicular versus parallel double plating methods for type C distal humeral fractures[J]. Chinese medical journal, 2013, 126(12): 2337-2342
Authors:LAN Xi  ZHANG Li-hai  TAO Sheng  ZHANG Qun  LIANG Xiang-dang  YUAN Bang-tuo  XU Wen-peng  YIN Peng  TANG Pei-fu
Affiliation:LAN Xia (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); ZHANG Li-hai (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); TAO Sheng (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); ZHANG Qun (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); LIANG Xiang-dang (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); YUAN Bang-tuo (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China); XU Wen-peng (Department of Orthopedics, Chinese People's Liberation Army General Hospital, Beijing 100853, China);
Abstract:Background Double plate osteosynthesis is the standard treatment for intra-articular fractures of the distal humerus.However,there is still controversy concerning dual plate positions in terms of providing optimal stability.The purpose of this retrospective study was to compare the clinical outcomes in patients with type C intra-articular distal humeral fractures using perpendicular and parallel plating methods.Methods Between March 2008 and June 2011,a total of 45 patients with type C distal humerus fractures were treated using two different dual plating methods.Of them,24 patients were treated by perpendicular plating (group Ⅰ) and 21 patients were treated by parallel plating (group Ⅱ).The surgical time,blood loss,and union time were compared between the two groups.The fiexion-extension arc,the total range of flexion and extension at the end of follow-up were compared between the two groups.The Mayo Elbow Performance Score (MEPS) was used to determine the elbow functional results.Results All patients were followed up.The mean duration of follow-up was 16 months (range 12-25 months) in group Ⅰ and 15.5 months in group Ⅱ (range 12-25 months).There were no significant differences in the surgical time,blood loss,and the bone union time between the two groups.In group Ⅰ,the mean elbow flexion-extension arc was 101° and the mean MEPS was 85 points.The rate of excellent and good results was 87.5%.In group Ⅱ,the mean flexion-extension arc was 100° and the mean MEPS was 86.1 points.The rate of excellent and good results was 90.5%.There were no significant differences in the MEPS,flexion-extension arc,and the total range of flexion and extension between the two groups.Conclusions Perpendicular and parallel plate configurations with the appropriate surgical techniques can provide anatomical reconstruction and stable fixation of type C intra-articular distal humeral fractures and allow early mobilization of the elbow after an operation.The occurrence of post-operative elbow stiffness can be reduced and good outcomes can be obtained.
Keywords:distal humerus  elbow joint  fractures, comminuted  bone plates  range of motion, articular
本文献已被 维普 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号