Aneurysm formation of pericardial patch in Manouguian procedure |
| |
Authors: | Hamidreza Pouraliakbar Maryam Pourmojib Yousef Rezaei Saeid Hosseini |
| |
Affiliation: | 1. Rajaie Cardiovascular Medical and Research Center, Tehran, Iran;2. Heart Valve Disease Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran |
| |
Abstract: | ![]() Pericardial patch has been used to repair cardiac defects; however, its strength as an aortoplasty patch to tolerate systemic pressure is a matter of debate. We report an aneurysmal dilatation of pericardial patch in aortoplasty. Our patient was a 56-year-old female known case of rheumatic heart disease that underwent redoes mitral and aortic valve replacements along with Manouguian aortoplasty at the age of 44?years old. After 2?months, she was readmitted with a diagnosis of endocarditis. Echocardiography revealed a small cavity in the posterior wall of the aorta. She responded to medical therapy and discharged in a good condition. Twelve years later, she was scheduled to undergo reoperation due to a severe paraprosthetic aortic valve leakage and a pericardial patch aneurysm. The leaking prosthetic aortic valve was explanted and the aneurysmal tissue was replaced with a polyethylene terephthalate patch. |
| |
Keywords: | Aortic valve replacement Manouguian procedure Pericardial patch aneurysm |
本文献已被 ScienceDirect 等数据库收录! |