Abstract: | BACKGROUND: Haemodynamic and respiratory effects of a CO2 pneumoperitoneum (intra-abdominal pressure = 12 mmHg) associated to a head-up position(15 degrees ) were studied in 20 pigs using a Swan-Ganz catheter and the Single Breath Test for CO2. The pneumoperitoneum induced a moderate rise in mean arterial pressure (+17%) (P<0.001) without any variation in heart rate, cardiac output and systemic vascular resistances. RESULTS: The following respiratory effects were observed: an increase in PaCO2 (+20%) (P<0.001), PE'CO2 (+31%) (P<0.001), expired volume of CO2 (+28%) (P<0.001), arterial to end-tidal CO2 gradient (+80%) (P<0.001) and alveolar dead space (+40%) (P<0.001) occured. Alveolar ventilation remained stable. Finally and contrary to healthy human patient, intraperitoneal CO2 insufflation in pig induced slight haemodynamic changes and major respiratory modifications. CONCLUSION: Thus, our data do not support the conclusion that the pig is a reliable experimental model for studying the pathophysiology of CO2 pneumoperitoneum-induced changes in haemodynamic and respiratory parameters, in human patients. |
| |