首页 | 本学科首页   官方微博 | 高级检索  
     


Midterm Results of Large Diameter Biolox Forte Ceramic Head on Delta Ceramic Liner Articulation in Total Hip Arthroplasty
Authors:Bun-Jung Kang  Yong-Chan Ha  Sun-Chul Hwang  Young-Kyun Lee  Kyung-Hoi Koo
Affiliation:1. Department of Orthopaedic Surgery, Gyeongsang National University School of Medicine, Jinju, South Korea;2. Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea;3. Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
Abstract:
Seventy-nine patients (94 hips), who underwent cementless alumina-on-alumina total hip arthroplasty (THA) with the use of a 36-mm delta ceramic liner-on-alumina ceramic femoral head, were followed for an average of 6.5 years (range, 5–7.7 years). All acetabular and femoral components were bone-ingrown and neither pelvic nor femoral osteolysis was identified until the latest follow-up. The survivorship with revision surgery as an endpoint was 97.9% (95% confidence interval = 100%–95%). Ceramic related complications such as fracture and squeaking did not occur in any patient. The mid-term results of cementless THA with this type of ceramic articulation are encouraging.
Keywords:total hip arthroplasty   cementless   large diameter femoral head   delta liner