Midterm Results of Large Diameter Biolox Forte Ceramic Head on Delta Ceramic Liner Articulation in Total Hip Arthroplasty |
| |
Authors: | Bun-Jung Kang Yong-Chan Ha Sun-Chul Hwang Young-Kyun Lee Kyung-Hoi Koo |
| |
Affiliation: | 1. Department of Orthopaedic Surgery, Gyeongsang National University School of Medicine, Jinju, South Korea;2. Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea;3. Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea |
| |
Abstract: | Seventy-nine patients (94 hips), who underwent cementless alumina-on-alumina total hip arthroplasty (THA) with the use of a 36-mm delta ceramic liner-on-alumina ceramic femoral head, were followed for an average of 6.5 years (range, 5–7.7 years). All acetabular and femoral components were bone-ingrown and neither pelvic nor femoral osteolysis was identified until the latest follow-up. The survivorship with revision surgery as an endpoint was 97.9% (95% confidence interval = 100%–95%). Ceramic related complications such as fracture and squeaking did not occur in any patient. The mid-term results of cementless THA with this type of ceramic articulation are encouraging. |
| |
Keywords: | total hip arthroplasty cementless large diameter femoral head delta liner |
本文献已被 ScienceDirect 等数据库收录! |
|