水质分析中CODCr测定方法的优化 |
| |
引用本文: | 严英,严丹军,周海燕.水质分析中CODCr测定方法的优化[J].环境卫生工程,2003,11(3):164-165. |
| |
作者姓名: | 严英 严丹军 周海燕 |
| |
作者单位: | 上海市废弃物老港处置场,201302,上海 |
| |
摘 要: | 针对COD快速测定法对于中小规模实验室批量测试成本高的问题,我们研究了一种使标准法与分光光度法相结合的CODcr新测定方法。新的COD测定方法比传统的测定法可减少重铬酸钾、硫酸汞用量50%,硫酸用量减少51%,不仅节省费用,还可以减轻实验室对环境的污染。
|
关 键 词: | CODcr测定方法 水质分析 环境 适用范围 |
修稿时间: | 2002年10月30 |
Optimization of COD Determination Measure for Water Quality Analysis |
| |
Abstract: | On the question of high cost of Lab-batch test of fast determining COD measure for middling and small cities.A new determining measure combining standard method with spectrophotometic titration was carried out.Comparing with traditional method,the new measure can reduce 50% of K 2Cr 2O 7 and HgSO 2 amount,51% of H 2SO 4 amount,not only save cost,but also reduce environment pollution of laboratory. |
| |
Keywords: | Water quality analysis COD determination Heating flow back Titration Spectrophotometic titration |
本文献已被 CNKI 维普 万方数据 等数据库收录! |
|