首页 | 本学科首页   官方微博 | 高级检索  
     


Design and implementation of a system for treating paediatric patients with stereotactically-guided conformal radiotherapy
Authors:Elizabeth J. Adams   Bridget L. Suter   Alan P. Warrington   Peter Black   Frank Saran  Michael Brada
Affiliation:

a Joint Department of Physics, The Royal Marsden NHS Trust, Downs Road, Sutton, Surrey SM2 5PT, UK

b Department of Radiotherapy, The Royal Marsden NHS Trust, Downs Road, Sutton, Surrey SM2 5PT, UK

c Neuro-Oncology Unit, The Royal Marsden NHS Trust, Downs Road, Sutton, Surrey SM2 5PT, UK

Abstract:Background and purpose: Stereotactically-guided conformal radiotherapy (SCRT) allows the delivery of highly conformal dose distributions to localised brain tumours. This is of particular importance for children, whose often excellent long-term prognosis should be accompanied by low toxicity. The commercial immobilisation system in use at our hospital for adults was felt to be too heavy for children, and precluded the use of anaesthesia, which is sometimes required for paediatric patients. This paper therefore describes the design and implementation of a system for treating children with SCRT. This system needed to be well tolerated by patients, with good access for treating typical childhood malignancies.

Materials and methods: A lightweight frame was developed for immobilisation, with a shell-based alternative for patients requiring general anaesthetic. Procedures were set up to introduce the patients to the frame system in order to maximise patient co-operation and comfort. Film measurements were made to assess the impact of the frame on transmission and surface dose. The reproducibility of the systems was assessed using electronic portal images.

Results: Both frame and shell systems are in clinical use. The frame weighs 0.6 kg and is well tolerated. It has a transmission of 92–96%, and fields which pass through it deliver surface doses of 58–82% of the dose at dmax, compared to 18% when no frame is present. However, the frame is constructed to maximise the availability of unobstructed beam directions. Reproducibility measurements for the frame showed a mean random error of 1.0±0.2 mm in two dimensions (2D) and 1.4±0.7 mm in 3D. The mean systematic error in 3D was 2.2 mm, and 90% of all overall 3D errors were less than 3.4 mm. For the shell system, the mean 2D random error was 1.5±0.2 mm.

Conclusions: Two well-tolerated immobilisation devices have been developed for fractionated SCRT treatment of paediatric patients. A lightweight frame system gives a wide range of possible unobstructed beam directions, although beams that intersect the frame are not precluded, provided that output corrections are applied. A shell system allows the use of general anaesthesia. Both systems give reproducible immobilisation to complement the high-precision treatment delivery.

Keywords:Fractionated stereotactic radiotherapy   Immobilisation   Paediatric radiotherapy   Patient fixation   Conformal radiotherapy
本文献已被 ScienceDirect 等数据库收录!
正在获取相似文献,请稍候...
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号