摘    要:
目的 评价3.0T TOF-MRA在支架辅助弹簧圈栓塞颅内动脉瘤术后随访中的应用价值。方法 对32例在笔者医院行颅内动脉瘤支架辅助弹簧圈栓塞术后6个月~2年的患者进行影像学随访,行3.0T TOF-MRA及数字减影血管造影(DSA)检查。以DSA结果为金标准,对MRA的影像质量及结果进行比较分析。结果 (1)3.0T TOF-MRA判断支架辅助弹簧圈栓塞术后栓塞情况的准确度为37.5%,与DSA比较差异有统计学意义(P < 0.05);结合原图像(SI)观察后,准确度提高到75.0%,与DSA比较差异无统计学意义(P > 0.05)。(2)3.0T TOF-MRA对判断术后载瘤动脉通畅性的准确率为37.5%,与DSA比较差异有统计学意义(P < 0.05)。结论 3.0T TOF-MRA结合原图像(SI)观察在评估支架辅助弹簧圈栓塞颅内动脉瘤术后栓塞情况的准确度高,可作为一种无创随访手段;但对判断载瘤动脉通畅性的准确度低,通过优化序列参数的方法可能得到改善。

关 键 词:颅内动脉瘤  磁共振血管成像  数字减影血管造影  血管内栓塞  随访研究
收稿时间:2017-01-14
修稿时间:2017-01-19

Application of 3.0T TOF MRA in the Follow-up of Endovascular Embolization for the Intracranial Aneurysm
Song Weijian,Li Baomin,Hu Shen. Application of 3.0T TOF MRA in the Follow-up of Endovascular Embolization for the Intracranial Aneurysm[J]. Journal of Medical Research, 2017, 46(10): 129-134
Authors:Song Weijian  Li Baomin  Hu Shen
Affiliation:Department of Neurosurgery, The Sixth People''s Hospital of Shenzhen, Guangdong 518052, China,Department of Neurosurgery, The Sixth People''s Hospital of Shenzhen, Guangdong 518052, China,Department of Neurosurgery, The Sixth People''s Hospital of Shenzhen, Guangdong 518052, China,Department of Neurosurgery, The Sixth People''s Hospital of Shenzhen, Guangdong 518052, China and Department of Neurosurgery, The Sixth People''s Hospital of Shenzhen, Guangdong 518052, China
Abstract:
Objective To evaluate the application of 3.0T TOF Magnetic resonance angiography (MRA) in the follow-up of the intracranial aneurysm with stent-assisted coil embolization. Methods In our hospital,32 patients who underwent intracranial aneurysm embolization with stent-assisted coil were followed up for 6m~2y with radiologic examination. All patients were followed up with 3.0T TOF-MRA and Digital subtraction angiography(DSA)examination. DSA served as the golden standard. The MRA image quality and the results were compared. Results (1)The accuracy of 3.0T TOF-MRA to determine the situation of the intracranial aneurysms with embolization was 37.5%, there was significant difference compared with DSA (P<0.05). The accuracy improved to 75.0% Combinated with SI(source image), there was no significant difference compared with DSA (P>0.05). (2)The accuracy of 3.0T TOF-MRA to determine the patency of the parent artery was 37.5%, there was significant difference compared with DSA (P<0.05). Conclusion The accuracy of 3.0T TOF-MRA+SI to evaluate the situation of the intracranial aneurysms with stent-assisted coil embolization was high. We can use 3.0T TOF-MRA+SI as a Noninvasive means for follow-up. The accuracy of 3.0T TOF-MRA to evaluate the patency of the parent artery was low, we may obtain better image by optimizing the sequence parameters.
Keywords:Intracranial aneurysm  Magnetic resonance angiography  Digital subtraction angiography  Endovascular embolization  Follow-up
点击此处可从《医学研究杂志》浏览原始摘要信息
点击此处可从《医学研究杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号