首页 | 本学科首页   官方微博 | 高级检索  
     

人工晶状体断襻的术中处理
引用本文:孙勇,甫拉提·阿布都热衣木,刘刚,秦艳莉,万新娟. 人工晶状体断襻的术中处理[J]. 国际眼科杂志, 2012, 12(11): 2194-2195
作者姓名:孙勇  甫拉提·阿布都热衣木  刘刚  秦艳莉  万新娟
作者单位:中国新疆维吾尔自治区乌鲁木齐市,新疆维吾尔自治区人民医院眼科; 中国上海市,上海交通大学生物医学工程学院;中国新疆维吾尔自治区乌鲁木齐市,新疆维吾尔自治区人民医院眼科;中国新疆维吾尔自治区乌鲁木齐市,新疆维吾尔自治区人民医院眼科;中国新疆维吾尔自治区乌鲁木齐市,新疆维吾尔自治区人民医院眼科;中国新疆维吾尔自治区乌鲁木齐市,新疆维吾尔自治区人民医院眼科
摘    要:目的:探讨人工晶状体植入时出现断襻的术中处理方法。方法:回顾总结2006-03/2011-05的25例25眼人工晶状体植入时出现断襻的术中处理方法:其一是将断襻人工晶状体植入囊袋内(23眼),其二是一期或二期更换断襻人工晶状体(2眼)。结果:在25眼中,其中1眼术中进行人工晶状体的更换,1眼术后第3d人工晶状体向下发生严重脱位,进行了人工晶状体的更换,2眼人工晶状体发生轻微移位,余21眼未发生人工晶状体移位;术后1mo矫正视力0.8~1.0者8眼,0.5~者14眼,0.2者1眼(合并有糖尿病视网膜病变),23眼均未发生人工晶状体明显移位;术后6mo随访的15眼均未发生人工晶状体明显移位。结论:将断襻人工晶状体植入囊袋内合适的位置,大多数人工晶状体不发生移位或不影响术后视力的提高,可以作为手术应急的一种选择。

关 键 词:人工晶状体  断襻  处理
收稿时间:2012-08-10
修稿时间:2012-10-19

Dealing with the intraocular lens with broken loop during surgery
Yong Sun,Fulati·Abudureyimu,Gang Liu,Yan-Li Qin,Xin-Juan Wan. Dealing with the intraocular lens with broken loop during surgery[J]. International Eye Science, 2012, 12(11): 2194-2195
Authors:Yong Sun  Fulati·Abudureyimu  Gang Liu  Yan-Li Qin  Xin-Juan Wan
Affiliation:Department of Ophthalmology, the People's Hospital of Xinjiang Uygur Autonomous Region, Urumchi 830001,Xinjiang Uygur Autonomous Region, China; School of Biomedical Enginering, Shanghai Jiao Tong University, Shanghai 200240, China;Department of Ophthalmology, the People's Hospital of Xinjiang Uygur Autonomous Region, Urumchi 830001,Xinjiang Uygur Autonomous Region, China;Department of Ophthalmology, the People's Hospital of Xinjiang Uygur Autonomous Region, Urumchi 830001,Xinjiang Uygur Autonomous Region, China;Department of Ophthalmology, the People's Hospital of Xinjiang Uygur Autonomous Region, Urumchi 830001,Xinjiang Uygur Autonomous Region, China;Department of Ophthalmology, the People's Hospital of Xinjiang Uygur Autonomous Region, Urumchi 830001,Xinjiang Uygur Autonomous Region, China
Abstract:AIM:To evaluate how to deal with the intraocular lens(IOL)with broken loop during surgery.

METHODS: The ways how to deal with the IOL with broken loop during the surgery of twenty-five patients twenty-five eyes from March 2006 to May 2011 were reviewed and summarized: one way was that IOL with broken loop were implanted into capsules(twenty-three eyes), another way was that IOL with broken loop were replaced in surgery or after operation(two eyes).

RESULTS: From the twenty-five eyes, one IOL with broken loop was replaced in surgery, one IOL with broken loop was replaced the third day after operation because of the serious dislocation downwards, the rest were on their locations; one month after operation eight eyes had best-corrected visual acuity with spectacles of 0.8-1.0, fourteen eyes were 0.5-0.8, only one eye was 0.2(combining with diabetic retinopathy), all were on their locations; six months after operation fifteen eyes were on their locations.

CONCLUSION: Most of IOLs with broken loop would neither dislocate nor affect the increase of visual acuity if they are implanted to suitable location in capsule, it is one of choice to deal with the emergency.

Keywords:intraocular lens   broken loop   deal with
本文献已被 维普 等数据库收录!
点击此处可从《国际眼科杂志》浏览原始摘要信息
点击此处可从《国际眼科杂志》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏