首页 | 本学科首页   官方微博 | 高级检索  
     

应用三维磁导航系统标测和消融快速性心律失常的初步经验
引用本文:喻荣辉,马长生,董建增,刘兴鹏,汤日波,龙德勇,田颖,张铭,史力生,郑斌,陶海龙. 应用三维磁导航系统标测和消融快速性心律失常的初步经验[J]. 中国心脏起搏与心电生理杂志, 2009, 23(3): 229-232
作者姓名:喻荣辉  马长生  董建增  刘兴鹏  汤日波  龙德勇  田颖  张铭  史力生  郑斌  陶海龙
作者单位:首都医科大学附属北京安贞医院心内科,北京市心肺血管疾病研究所,北京,100029
摘    要:目的观察三维磁导航系统标测和消融快速性心律失常的疗效。方法结合NiobeII磁导航系统和CARTO-RMT电解剖标测系统,采用4mm-顶端的NaviStar-RMT标测和消融导管进行射频消融治疗快速性心律失常。结果10例患者,男6例,女4例。房室结折返性心动过速4例,其中1例合并阵发性心房颤动,左侧房室旁道2例,右侧房室旁道1例,典型心房扑动2例,右室流出道室性心动过速1例。磁导航系统遥控操作,10例均完成电生理标测。9例消融成功,失败1例为心房扑动患者,换用NaviStar盐水灌注导管后消融成功。导管操作时间93±33.1min,X线曝光时间12.5±6.5min。随访6个月无复发。结论对于快速性心律失常,应用磁导航系统可进行有效和安全的三维标测和消融。

关 键 词:电生理学  电解剖标测  磁导航系统  导管消融,射频电流

Initial experience of three-dimension remote-guided magnetic catheter navigation system in mapping and ablation of tachycardia
YU Rong-hui,MA Chang-sheng,DONG Jian-zeng,LIU Xing-peng,TANG Ri-bo,LONG De-yong,TIAN Ying,ZHANG Ming,SHI Li-sheng,ZHENG Bin,TAO Hai-long. Initial experience of three-dimension remote-guided magnetic catheter navigation system in mapping and ablation of tachycardia[J]. Chinese Journal of Cardiac Pacing and Electrophysiology, 2009, 23(3): 229-232
Authors:YU Rong-hui  MA Chang-sheng  DONG Jian-zeng  LIU Xing-peng  TANG Ri-bo  LONG De-yong  TIAN Ying  ZHANG Ming  SHI Li-sheng  ZHENG Bin  TAO Hai-long
Affiliation:( Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China)
Abstract:Objective To investigate the effect of three-dimension remote-guided magnetic catheter navigation system in mapping and ablation of tachycardia. Methods CARTO-RMT electroanatomical mapping system was integrated with Niobe Ⅱ magnetic catheter navigation system, a 4mm-tip NaviStar-RMT mapping and ablation catheter was performed to ablate. Results Ten patients were enrolled,including 6 female and 4 male. After electrophysiological examination, atrioventricular nodal reentrant tachycardia was found in 4 patients, and one of them was accompanied with paroxymal atrial fibrillation, left accessory pathways was found in 2 patients, right accessory pathway was found in 1 patient, typical atrial flutter was found in 2 patients, ventricular tachycardia originated from right ventricular outflow tract was found in 1 patient. Ablation was successful in 9 patients, and failed in 1 patient, the failed case was a patient with atrial flutter, but successed after replacement of a NaviStar irrigating catheter. The average procedure time was 93 ± 33.1 min, the total X-ray exposure time was 12.5 ±6.5 min. No recurrence was found in follow-up of 6 months. Conclusion Applying three-dimension remote-guided magnetic catheter navigation system in mapping and ablation of tachycardia is effective and safe.
Keywords:Electrophysiology  Electroanatomical mapping  Magnetic navigation system  Catheter ablation, radiofrequency current
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号