首页 | 本学科首页   官方微博 | 高级检索  
     


Effects of biofilm formation on haemodialysis monitor disinfection.
Authors:Gianni Cappelli  Luisa Sereni  Maria Grazia Scialoja  Massimo Morselli  Salvatore Perrone  Angela Ciuffreda  Massimo Bellesia  Paola Inguaggiato  Alberto Albertazzi  Ciro Tetta
Affiliation:Department of Nephrology, University Hospital of Modena, Italy.
Abstract:
BACKGROUND: Biofilms are composed of communities of micro-organisms adhering to essentially any surface. We evaluated whether biofilm formation in the hydraulic circuit of a purposely contaminated haemodialysis monitor would modify the efficacy of different disinfection modalities against bacteria and endotoxin concentrations. METHODS: A water-borne Pseudomonas aeruginosa (109) suspension was recirculated for 1 h and was left standing for 72 h (stationary phase) in the hydraulic circuit of the monitor. The monitor was then washed and disinfected by different physical (heat, 85 degrees C) or chemical (hypochlorite or peracetic acid) disinfection modalities (protocol A). In protocol B, the bacterial suspension was also recirculated for 1 h, but the monitor was then immediately washed and disinfected by different chemical disinfection modalities (hypochlorite or peracetic acid). RESULTS: Biofilm formation was revealed by scanning and confocal laser electron microscopy after the stationary phase (protocol A), but was absent when the monitor was immediately washed and disinfected (protocol B). In the presence of biofilm (protocol A), heat in association with citric acid was the most effective modality for reducing both colony forming units and endotoxin concentrations, whereas heat by itself was the least effective method of disinfection. Dwelling (60 h) with diluted peracetic acid completely prevented the formation of biofilm. In the absence of biofilm (protocol B), chemical disinfection proved to be effective against both colony forming units and endotoxin concentrations. CONCLUSIONS: We found that biofilm formation may markedly reduce the efficacy of presently available disinfection modalities. Therefore, different disinfection modalities and the combined action of descaling (by citric acid) and disinfection (physical/chemical agents) should be used periodically in haemodialysis monitors. In addition, dwelling with diluted peracetic acid should be adopted whenever monitors are not in use.
Keywords:biofilm   contamination   cytokine   disinfection   microinflammation   monitor
本文献已被 Oxford 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号