摘    要:目的用HPLC法测定复方氢化可的松栓剂中维生素E(VE)含量。方法采用高效液相色谱法。色谱柱:KromasilC18柱(4.6mm×200mm,5μm);流动相为甲醇,检测波长为285nm。流速:1.0ml/min;柱温:室温。结果VE浓度在0.30~1.60μg范围与峰面积呈线性关系(r=0.99995)。结论此方法准确、灵敏、快速、简便。

关 键 词:维生素E  高效液相色谱法  复方氧化可的松栓剂

Determination of Vitamin E in Compound Hydrocortisone Suppository by HPLC
Institution:LIU Ren -jun ,MU Fang- ying. (Jilin Provincial Chinese Traditional Medicine Hospital, Changchun Jilin 130021, China )
Abstract:Objective To use high performance liquid chromatography(HPLC) method for detecting vitamin E in compound hydrocortisone suppository. Methods HPLC method was applied on the Kromasil C18 column ( 4. 6 mm × 200 mm ,5 μm) at room temperature, the mobile phase was methanol, the detection wavelength was 285 nm, flow rate was 1.0 ml/min. Results There was a linear relationship between concentration of vitamin E and peak area in the range of 0. 30 - 1.60 μg( r = 0. 999 95 ). Conclusion This method is accurate, sensitive , easy to operate.