Abstract: | PURPOSE: To investigate the efficacy and safety of implantation of an iris-claw phakic intraocular lens (PIOL), Artisan Myopia, in Asian eyes. SETTING: Minamiaoyama Eye Clinic, Tokyo, Japan. METHODS: Forty-four eyes of 32 Japanese patients and 1 Korean patient with high myopia had Artisan Myopia lens implantation to correct their refractive errors. Lens models, 5/8.5 or 6/8.5 (optic diameter/overall diameter), were chosen as standard lens model. A smaller lens model (5/7.5-Artisan Myopia Small) was implanted in eyes with corneal diameter less than 11.0 mm. Postoperative examinations were performed on 1 day, 1 week, 1 month, 3 months, 6 months, 1 year, and 2 years after surgery. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), manifest refraction, corneal endothelial cell counts, intraocular pressure, and complications were evaluated. RESULTS: Artisan Myopia Small lenses were implanted in 4 eyes (9.1%) and 8.5 mm diameter lenses were implanted in 40 eyes. Preoperative UCVA (logMAR) improved from 1.57 to 0.09 at 1 month after surgery and no regression was observed thereafter. Postoperative manifest refraction was -1.02 +/- 0.87 D (-3.25 to -0.00 D), and within 1.0 D in 20 eyes (55.6%), within 2.0 D in 32 eyes (88.9%) at 1 month after surgery, and stable during the follow-up period. The final BCVA decreased 2 lines in 2 eyes (4.5%) due to progression of age-related cataract. No serious complications such as angle closure or progressive endothelial cell loss were observed. CONCLUSION: Implantation of an Artisan iris-claw PIOL implantation may be a safe and effective procedure for Asian eyes. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|