首页 | 本学科首页   官方微博 | 高级检索  
     


A retrospective analysis comparing set up errors from standard versus customised headrests for head and neck radiotherapy
Affiliation:1. Department of Radiotherapy at The Royal Marsden NHS Foundation Trust, Sutton, UK;2. The Institute of Cancer Research, London, UK;3. Joint Department of Physics at The Royal Marsden NHS Foundation Trust and The Institute of Cancer Research, London, UK;4. Department of Statistics at The Royal Marsden NHS Foundation Trust, Sutton, UK;1. Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany;2. Department of Diagnostic and Interventional Radiology and Neuroradiology, German Armed Forces Hospital Ulm, Oberer Eselsberg 40, 89081 Ulm, Germany;3. Department of Diagnostic and Interventional Radiology, University Hospital Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany;4. Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070 Würzburg, Germany
Abstract:IntroductionIn response to advice from The National Institute for Health and Care Excellence (1) to reduce hospital visits during COVID-19, standard headrests were introduced for head and neck radiotherapy within Northern Centre for Cancer Care (NCCC). The standard headrest requires one mould room appointment compared to 3 appointments with customised headrests.MethodsTwo groups of 10 patients treated between December 2019 and June 2020 were retrospectively analysed by 1 observer. Groups were stratified according to age, sex and tumour site. One group had customised headrest and the other had standard headrest. Five hundred and forty seven cone beam computed tomography images were reviewed. A 6 Degree of Freedom match was performed then chin, shoulder and spine position were assessed using dosimetrist drawn structures. Structures out of the tolerance were recorded. A chi-squared test was used for statistical analysis.ResultsThe out of tolerance chin position count recorded was 21 for customised headrest and 36 for standard headrest, p-value 0.046. The shoulder position count was 13 for customised headrest and 77 for standard headrest p-value <0.001. The spine position count was 3 for CHR and 21 for standard headrest, p-value <0.001. This means the headrests compared are not equivalent in terms of set up reproducibility. Overall the standard headrest group had 10 set-up re-scans and no set up re-scans were recorded in the customised headrest group.ConclusionFewer hospital visits with SHR reduce patient exposure to COVID-19. However, CHR provided a more reliable level of immobilisation in this study.Implications for practiceThe radiotherapy service will be reviewed in line with these findings.
Keywords:Head and neck  Radiotherapy  Headrests  Immobilization  Set-up errors  3DOF"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_eRe00RQMRy"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Three Degrees of Freedom  6DOF"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_97PGotDofV"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Six Degrees of Freedom  CBCT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_lYkbZjg9rb"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Cone Beam Computerised Tomography  CHR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_9ImBNpK5Wt"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Custom Headrest  CV"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_SOKuXd2iLm"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Coefficant of Variation  ESTRO"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_4kCrImx1u2"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  European Society for Therapeutic Radiology and Oncology  HN"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_obeP4RO0kB"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Head and Neck  MRN"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_AYmFUZ258y"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Medical Records Number  OAR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_DNS74laEQj"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Organ at Risk  OOT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_lP6gDpSi19"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Out of Tolerance  SD"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_5tpxYe6Wiy"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Standard Deviation  SHR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_0UiNTBKX6r"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Standard Headrest  VMAT"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  pc_Scerg27jS6"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Volume Modulated Arc Therapy
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号