Hybrid IMRT plans--concurrently treating conventional and IMRT beams for improved breast irradiation and reduced planning time |
| |
Authors: | Mayo Charles S Urie Marcia M Fitzgerald Thomas J |
| |
Affiliation: | Department of Radiation Oncology, University of Massachusetts Medical School, UMASS/Memorial Medical Center, 55 Lake Avenue North, Worcester, MA 01655, USA. mayoc@ummhc.org |
| |
Abstract: | PURPOSE: To evaluate a hybrid intensity modulated radiation therapy (IMRT) technique as a class solution for treatment of the intact breast. METHODS AND MATERIALS: The following five plan techniques were compared for 10 breast patients using dose-volume histogram analysis: conventional wedged-field tangents (Tangents), forward-planned field-within-a-field tangents (FIF), IMRT-only tangents (IMRT tangents), conventional open plus IMRT tangents (4-field hybrid), and conventional open plus IMRT tangents with 2 anterior oblique IMRT beams (6-field hybrid). RESULTS: The 4-field hybrid and FIF achieved dose distributions better than Tangents and IMRT tangents. The volume of tissue outside the planning target volume receiving > or =110% of prescribed dose was largest for IMRT tangents (average 158 cc) and least for 6-field hybrid (average 1 cc); the FIF and 4-field hybrid were comparable (average 15 cc). Heart volume > or =30 Gy averaged 13 cc for all techniques, except Tangents, for which it was 32 cc. Average total lung volume > or =20 Gy was 7% for all. Contralateral breast doses were < 3% for all. Planning time for hybrid techniques was significantly less than for conventional FIF technique. CONCLUSIONS: The 4-field hybrid technique is a viable class solution. The 6-field hybrid technique creates the most conformal dose distribution at the expense of more normal tissue receiving low dose. |
| |
Keywords: | |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|