首页 | 本学科首页   官方微博 | 高级检索  
     

基于FT-CMR的心脏功能评估参数对心房颤动冷冻球囊消融患者治疗后复发的预测效能分析
引用本文:于颖慧,李晓刚,李小伟,张璐,何健. 基于FT-CMR的心脏功能评估参数对心房颤动冷冻球囊消融患者治疗后复发的预测效能分析[J]. 广东医学, 2023, 44(2): 235-239. DOI: 10.13820/j.cnki.gdyx.20222852
作者姓名:于颖慧  李晓刚  李小伟  张璐  何健
作者单位:秦皇岛市第一医院 1心血管内科二病区, 2心血管外科(河北秦皇岛 066000)
摘    要:
目的 探讨分析基于心脏磁共振特征追踪技术(FT-CMR)的心脏功能评估参数对心房颤动冷冻球囊消融患者治疗后复发的预测效能。方法 选取2019年6月至2020年12月收治的126例预行冷冻球囊消融术的心房颤动患者为研究对象,术前均进行心脏磁共振检查,根据术后6个月内患者有无复发将其分为窦性心律组72例和房颤复发组54例。比较两组患者左心房应变及应变率参数,采用FT-CMR评估患者心脏功能,并进行单因素、多因素logistic回归分析,探讨FT-CMR心脏功能评估参数对心房颤动冷冻球囊消融术后复发的预测价值。结果 房颤复发组患者女性、高血压、糖尿病、非阵发性心房颤动比例显著高于窦性心律组(P<0.05)。房颤复发组患者左心房总应变(Es)、左心房正向应变率峰值(SRs)、左心房被动应变(Ee)、心室舒张早期负向应变率峰值(SRe)、左心房整体纵向应变(PLAS)参数值低于窦性心律组(P<0.05)。Logistic多因素回归分析结果显示,性别(OR=3.511,95%CI:1.036~11.906)、PLAS(OR=1.089,95%CI:1.039~1.141)是心房颤动冷冻...

关 键 词:心脏磁共振特征追踪技术  心脏功能  心房颤动  冷冻球囊消融术  术后复发  预测价值

Predictive efficacy of FT-CMR-based cardiac function assessment parameters for recurrence of atrial fibrillation after cryoballoon ablation
YU Ying-hui☆,LI Xiao-gang,LI Xiao-wei,ZHANG Lu,HE Jian. Predictive efficacy of FT-CMR-based cardiac function assessment parameters for recurrence of atrial fibrillation after cryoballoon ablation[J]. Guangdong Medical Journal, 2023, 44(2): 235-239. DOI: 10.13820/j.cnki.gdyx.20222852
Authors:YU Ying-hui☆  LI Xiao-gang  LI Xiao-wei  ZHANG Lu  HE Jian
Affiliation:Cardiovascular Medicine Second Ward, the First Hospital of Qinhuangdao, Qinhuangdao 066000, Hebei, China
Abstract:
Objective To analyze the predictive efficacy of cardiac magnetic resonance feature tracking (FT-CMR)-based cardiac function assessment parameters for recurrence of atrial fibrillation after cryoballoon ablation. Methods A total of 126 patients with atrial fibrillation who underwent cryoballoon ablation from June 2019 to December 2020 were selected. Cardiac magnetic resonance examination was performed before operation. Patients were divided into sinus rhythm group (n=72) and recurrence group (n=54) according to the recurrence of atrial fibrillation. The left atrial strain and strain rate parameters of the two groups were compared, and FT-CMR was used to evaluate the cardiac function of the patients. Predictive value of cardiac function assessment parameters of CMR for postoperative recurrence of atrial fibrillation after cryoballoon ablation was analyzed. Results The proportions of gender, hypertension, diabetes and non-paroxysmal atrial fibrillation in the recurrence group were significantly higher than those in the sinus rhythm group (P<0.05). The parameter values of Es, SRs, Ee, SRe, and PLAS in the recurrence group were significantly lower than those in the sinus rhythm group (P<0.05). Logistic multivariate regression analysis showed that gender (OR=3.511, 95%CI: 1.036-11.906) and PLAS (OR=1.089, 95%CI: 1.039-1.141) were independent risk factors associated with recurrence after cryoballoon ablation (P<0.05). When the PLAS cut-off value of the cardiac function assessment parameter of FT-CMR was 12, the area under the ROC curve for predicting the recurrence of atrial fibrillation after cryoballoon ablation was 0.82 (95%CI: 1.237-3.149) with sensitivity of 83.26% and specificity of 78.45%. Conclusion Cardiac function assessment parameters based on FT-CMR have good predictive value for the recurrence of atrial fibrillation after cryoballoon ablation, and the overall longitudinal strain reduction of the left atrium has an important reference value for predicting postoperative recurrence of atrial fibrillation.
Keywords:cardiac magnetic resonance feature tracking technology   cardiac function   atrial fibrillation   cryoballoon ablation   postoperative recurrence   predictive value  
点击此处可从《广东医学》浏览原始摘要信息
点击此处可从《广东医学》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号