首页 | 本学科首页   官方微博 | 高级检索  
     


Ictal recordings of ambulatory cassette EEG with sphenoidal electrodes in temporal lobe epilepsy: comparison with intensive videomonitoring
Authors:A. Tuunainen  U. Nousiainen
Affiliation:Vaajasalo Hospital, Department of Clinical Neurophysiology, Kuopio, Finland
Abstract:
Seventy-three seizures in 18 epilepsy patients were studied by analyzing the ictal findings of 8-channel ambulatory EEG (A/EEG) and adjacent 16-channel intensive videomonitoring (IVM). With IVM and A/EEG analysis, accuracy was excellent for determining the lateralization of seizure progression; whereas at seizure onset and post-ictal slowing, accuracy was poor. No false lateralization was found in A/EEG compared with IVM or lateralization according to patient data, and in seizure lateralization the interpretation of A/EEG was discordant in only 3 seizures with IVM analysis. According to our study, ictal 8-channel A/EEG with sphenoidal electrodes is not suitable for localization of temporal lobe foci, but is reliable for lateralization analysis.
Keywords:ambulatory cassette EEG    intensive videomonitoring    sphenoidal electrodes    seizures
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号