10 years results of an uncemented metaphyseal fit modular stem in elderly patients |
| |
Authors: | Basilio J De la Torre Manuel Chaparro Juan O Romanillos Sara Zarzoso Margarita Mosquera Gil Rodriguez |
| |
Affiliation: | 1Department of Orthopedic Surgery, University Hospital of Guadalajara, Alcala University, Guadalajara;2Department of Orthopedics, Faculty of Medicine, Alcala University, Alcala de Henares, Madrid, Spain;3Department of Preventive Medicine and Public Health, Alcorcón University Hospital, Alcorcón, Madrid, Spain |
| |
Abstract: |
Background:There are concerns with regard to the femoral fixation in cementless total hip arthroplasty in elderly patients. We report a retrospective analysis of clinical and radiological results of uncemented metaphyseal fit modular stem in elderly patients irrespective of anatomic characterstics of proximal femur.Materials and Methods:This study reviews the outcomes of 60 primary hip replacements using a metaphyseal fit modular stem (third-generation Omniflex stem) conducted in 54 patients, of age 75 years or older. After a mean follow-up of 10,4 years, complete clinical and radiographic records were available for 52 hips of 48 patients. The patients were evaluated by Harris Hip Score (HHS).Results:There was a significantly improved pain score and Harris Hip Score (41,6 to 83,2). Six stems (11.53%) were revised: four because of periprosthetic fracture; one stem was well fixed, but presented a large osteolytic lesion in the metaphyseal area and the last stem was revised because of aseptic loosening. Stem survival taking aseptic loosening as the end-point was 98%. Bone atrophy in the proximal femur caused by stress shielding was observed in 39 stems (75%), but there was no case of subtrochanteric stress shielding. Moreover, atrophy appeared within two years postoperatively, with no extension thereafter.Conclusions:We achieved good clinical and radiographic results by uncemented metaphyseal fit femoral stem regardless of patient''s age and femoral canal type. |
| |
Keywords: | Cementless femoral stem fixation elderly hydroxyapatite-coated stem stress shielding modular omniflex stem |
|
|