首页 | 本学科首页   官方微博 | 高级检索  
     

漏电流检测仪校准、检定的方法分析
引用本文:张志清. 漏电流检测仪校准、检定的方法分析[J]. 中国医疗器械信息, 2011, 17(4): 48-50
作者姓名:张志清
作者单位:山西省医疗器械检测中心,太原,030012
摘    要:
对漏电流检测仪进行校准、检定时,很多情况是接入被测设备单测试端进行测量,对如何接入校准、检定仪器双测试端进行测量,本文提出了相应的思路和方法。

关 键 词:漏电流检测仪  对地漏电流  外壳漏电流  患者漏电流  患者辅助电流

Leakage Current Detector Calibration, Verification Methods
ZHANG Zhi-qing. Leakage Current Detector Calibration, Verification Methods[J]. China Medical Devices Information, 2011, 17(4): 48-50
Authors:ZHANG Zhi-qing
Affiliation:ZHANG Zhi-qing ShanXi Center for Medical Devices Testing(Taiyuan 030012)
Abstract:
On the leakage current detector calibration,test,the leakage current detector in many cases access to the device under test is to measure a single test side,but how to access the calibration,testing instruments to measure two-Test side,this paper puts forward ideas and methods.
Keywords:leakage current detector  earth leakage current  enclosure leakage current  patient leakage current  patient auxiliary current
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号