摘    要:
本文报导了用国产气相色谱仪测定血清中甘油浓度的分析方法。该法线性范围为1.6~800μg/ml,日内误差与日间误差的CV均小于3%。回收率87%左右。可供血清中生理浓度或治疗浓度的甘油测定用,亦可用于氨基酸-甘油营养液的含量分析。

关 键 词:气相色谱法 甘油 血清

DETERMINATION OF GLYCEROL IN SERUM BY GAS CHROMATOGRAPHY
Yang Xiangqing,Cai Minghong,Liu Xinjian,Liu Lidong and Chen Gang. DETERMINATION OF GLYCEROL IN SERUM BY GAS CHROMATOGRAPHY[J]. Acta Nutrimenta Sinica, 1990, 12(1): 23-27
Authors:Yang Xiangqing  Cai Minghong  Liu Xinjian  Liu Lidong  Chen Gang
Abstract:
A gas chromatographic method has been developed for determining glycerin concentrations of both therapeutic and physiological levels in serum. The linear relationship was obtained in the range of 1.6-800 ug/ml and the coefficient variations determined within a day and between days were 2.2% and 2.4% respectively. Recoveries of glycerol from serum were about 87%.
Keywords:gas chromatography glycerol