Uroflowmetry in diagnosis of urinary stress incontinence in women]
Authors:J Mirończuk  A Lenczewski  Z Pieciukiewicz  M Jó?wik  W Lotocki
Affiliation:Kliniki Ginekologii i Po?oznictwa Septycznego, Bia?ymstoku.
Abstract:
The authors' aim was to evaluate the range of uroflowmetry in diagnostics of stress urinary incontinence (sui) in women. The examinations were carried out in 59 women with sui, aged from 35 to 45 years (group I). The control group consisted of 20 asymptomatic women (group II). To evaluate volumes of urine voided during micturition in a unit of time a urological flowmeter UF-1 (produced by COTM, Bia?ystok) was used. Numeric data of flow were analysed, as well as registered curves of flow were ascribed to one of the following flow patterns: normal, multi-peak or interrupted. The conducted studies revealed statistically significant differences in flow values in group I, compared to group II. A more frequent incidence of multi-peak and interrupted flow patterns was found in women with sui, which could be related to a neurogenic component in etiology of the disease.