首页 | 本学科首页   官方微博 | 高级检索  
     


MOSFET dosimetry for radiation dose assessment of bismuth shielding of the eye in children
Authors:Mukundan Srinivasan  Wang Page Inman  Frush Donald P  Yoshizumi Terry  Marcus Jeffrey  Kloeblen Emily  Moore Meredith
Affiliation:Department of Radiology, Duke University Medical Center, DUMC Box 3808, Durham, NC 27705, USA.
Abstract:OBJECTIVE: The purpose of our study was to measure radiation dose to the orbit during pediatric cranial CT with and without bismuth shielding using a novel dosimetry system. Cranial CT was performed on a pediatric anthropomorphic phantom, with and without bismuth eye shields. A solid-state metal oxide semiconductor field effect transistor (MOSFET) dosimeter was used to obtain real-time dose measurements. CONCLUSION: Bismuth shielding reduced radiation dose to the eye by up to 42%; shield artifact fell outside the diagnostic area of interest.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号