首页 | 本学科首页   官方微博 | 高级检索  
     


Biological Indices Evaluation of Various Treatment Techniques for Left-Sided Breast Treatment
Authors:Amitpal Singh Saini  Indra J. Das  Catherine S. Hwang  Matthew C. Biagioli  William E. Lee
Affiliation:1. Department of Radiation Oncology, Advent Health Cancer Institute, Orlando, Florida;2. Department of Medical Engineering, University of South Florida, Tampa, Florida;3. Department of Radiation Oncology, NYU Langone School of Medicine & Laura and Isaac Perlmutter Cancer Center, New York, New York;4. Department of Chemical & Biomedical Engineering, University of South Florida, Tampa, Florida
Abstract:
PurposeTo compare dose to organs at risk (OARs) and biological evaluation using normal tissue complication probability (NTCP) for left-sided breast radiation therapy in 4 techniques: supine free breathing (SFB), supine deep inspiration breath hold (SDIBH), prone free breathing (PFB), and prone deep inspiration breath hold (PDIBH).Methods and MaterialsTwenty-five patients with left-sided breast cancer suitable for this study underwent a computed tomography scan using SFB, SDIBH, PFB, and PDIBH. One radiation oncologist contoured the planning target volume and OAR (cardiac components). Dose-volume histograms and NTCPs for the heart, left ventricle (LV), left anterior descending artery (LAD), and left lung were calculated for all 4 techniques.ResultsThe mean heart dose in PDIBH is 0.77 Gy, which is statistically significantly lower than in SFB (1.88 Gy, P < .0001), SDIBH (0.97 Gy, P < .001), and PFB (0.85 Gy, P < .001). The mean left lung dose is 0.69 Gy in PFB and 0.88 Gy in PDIBH. PFB and PDIBH have statistically significantly lower doses compared with SFB (6.09 Gy, P < .0001) and SDIBH (5.41 Gy, P < .0001). The mean NTCP in SFB for the heart, LV, and LAD is 0.27%, 0.62%, and 4.23%, respectively, and it is negligible for other techniques.ConclusionsWe found that PDIBH had a dosimetrically lower mean dose for the heart and LV compared with the other 3 techniques. In addition, SDIBH, PFB and PDIBH had statistically significantly lower NTCP for the heart, LV, and LAD compared with SFB. NTCP for the left lung was statistically significantly lower for prone techniques compared with supine techniques. Therefore we concluded that, compared with SDIBH, PDIBH provides the added benefit of sparing the heart while keeping the benefit of sparing the lung as in the prone technique.
Keywords:Corresponding author: Amitpal Singh Saini   MS
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号