首页 | 本学科首页   官方微博 | 高级检索  
     

Airtraq(R)喉镜和Macintosh直接喉镜在经口气管插管时血流动力学的比较
引用本文:王勇,马武华,黎玉辉,王可佳,罗艳霞. Airtraq(R)喉镜和Macintosh直接喉镜在经口气管插管时血流动力学的比较[J]. 国际麻醉学与复苏杂志, 2011, 32(4): 405-408. DOI: 10.3760/cma.j.issn.1673-4378.2011.08.006
作者姓名:王勇  马武华  黎玉辉  王可佳  罗艳霞
作者单位:广州中医药大学第一附属医院麻醉科,510405
摘    要:
目的比较Airtraq(R)视频喉镜和Macintosh直接喉镜经口气管插管时心血管反应。方法40例拟择期经口气管插管全麻下手术的患者,按照随机数字表随机分为两组,Airtraq(R)组(A组)和Macintosh喉镜组(M组),每组20例。观察麻醉诱导前、诱导后、插管即刻、插管后1、3 min时的心率(HR)、血压和...

关 键 词:Airtraq(R)视频喉镜  Macintosh直接喉镜  经口气管插管  血流动力学反应

Comparison of hemodynamic responses to orotracheal intubation between using Airtraq(R) laryngoscope and Macintosh laryngoscope
WANG Yong,MA Wu-hua,LI Yu-hui,WANG Ke-jia,LU Yan-xia. Comparison of hemodynamic responses to orotracheal intubation between using Airtraq(R) laryngoscope and Macintosh laryngoscope[J]. international journal of anesthesiology and resuscitation, 2011, 32(4): 405-408. DOI: 10.3760/cma.j.issn.1673-4378.2011.08.006
Authors:WANG Yong  MA Wu-hua  LI Yu-hui  WANG Ke-jia  LU Yan-xia
Affiliation:WANG Yong,MA Wu-hua,LI Yu-hui,WANG Ke-jia,LU0 Yan-xia
Abstract:
bjective To compare the hemodynamic responses to orotracheal intubation between Airtraq(R)laryngoscope and Macintosh laryngoscope. Methods 40 patients scheduled for surgery under general anesthesia requiting orotracheal intubation were randomly allocated to undergo intubation using Airtraq (R)(group A, n=20) or Macintosh(group M, n=20) laryngoscope. The following data were recorded and analyzed: glottic exposure time, tracheal intubation time, blood pressure(BP) and heart rate(HR) before and after anesthetic induction, at intubation and thereafter at 1 and 3 min. The rate pressure product (RPP) at each measuring time point was calculated. Results There was no significant difference in the glottic exposure time between the two groups,but the intubation time in M group (10±4) s were significantly longer than that in A group (6±4) s. Compared with base value preinduction, BP, HR and RPP were significantly decreased in both groups.Glottic exposure and tracheal intubation caused significant increases in BP, HR,and RPP as compared with postinduction values. In group M, BP, HR and RPP at 3 min after indubation [SBP (106±17) mm Hg,DBP (65±10) mm Hg,MAP (78±19) nun Hg,HR (92±12) beat/min,RPP (9748±2072)]were significant higher than that with postinduction values [SBP (93±15) mm Hg,DBP(54±9) mm Hg,MAP(67±10) mm Hg,HR(85±12) beat/min,RPP(8117±1886)].But both A and M group,BP,HR and RPP at 5 min after indubation were no significant with postinduction values. Conclusion In comparison to the Macintosh laryngoscope, tracheal intubation with the Airtraq(R)laryngoscope resulted in less alterations in hemodynamic responses.
Keywords:Airtraq (R) laryngoscope  Macintosh laryngoscope  Orotracheal intubation hemodynamic responses
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号