首页 | 本学科首页   官方微博 | 高级检索  
     

计算机视觉食管曲张静脉压力检测技术的初步研究
引用本文:孔德润,张磊,张超,付忠谦,郝加虎,何兵兵,孙斌,谢岳,李盼,许建明. 计算机视觉食管曲张静脉压力检测技术的初步研究[J]. 中华消化内镜杂志, 2010, 28(11): 204-209. DOI: 10.3760/cma.j.issn.1007-5232.2011.04.010
作者姓名:孔德润  张磊  张超  付忠谦  郝加虎  何兵兵  孙斌  谢岳  李盼  许建明
作者单位:安徽医科大学第一附属医院消化科消化病重点实验室,合肥,230022;安徽医科大学第一附属医院肝胆外科,合肥,230022;中国科学技术大学电子科学与技术系;安徽医科大学公共卫生学院;
基金项目:教育部高等学校博士点专项基金安徽省教育厅自然科学重点研究项目资助
摘    要:
Objective To evaluate the clinical reliability and feasibility of computerized endoscopic balloon manometry in vitro and in vivo, in measurement of pressure of esophageal varices. Methods Computerized endoscopic balloon manometry was used to measure the pressure of variceal model with different diameter (3 mm, 6 mm and 8 mm) and intraluminal pressures (ranging from 8 to 36 mm Hg), and the findings were compared with actual pressures. The technique was also applied in 23 patients with liver cirrhosis and esophageal varices, and its correlation with hepatic venous pressure gradient and other factors related with varices bleeding. Results The study in vitro showed that the measured intraluminal pressure was correlated significantly with the actual value ( r ≥ 0. 993, P < 0. 001 ) without obvious measurement bias(95% CI = -0.13 cm H2O to 0. 33 cm H2O). The measurement in 23 patients were success with little variation coefficient (r≥0. 998) between repeated procedures. Regression analysis showed a good correlation between variceal pressure and hepatic venous pressure gradient (r=0. 858, P < 0. 001 ). A higher variceal pressure was strongly associated with presence of previous bleeding episodes, vascular diameter and presence of red color signs, but did not correlate with the parameter of Child-Pugh classification ( t = 0. 31, P =0. 76). Conclusion Computerized endoscopic balloon manometry is reliable and feasible to examine esophageal variceal pressure, and is very likely to be a valuable clinical index for variceal bleeding.

关 键 词:食管和胃静脉曲张   测压法   高血压,门静脉   

A new computerized endoscopic balloon manometry to detect esophageal variceal pressure: experimental validation and clinical feasibility
KONG De-run,ZHANG Lei,ZHANG Chao,FU Zhong-qian,HAO Jia-hu,HE Bing-bing,SUN Bin,XIE Yue,LI Pan,XU Jian-ming. A new computerized endoscopic balloon manometry to detect esophageal variceal pressure: experimental validation and clinical feasibility[J]. Chinese Journal of Digestive Endoscopy, 2010, 28(11): 204-209. DOI: 10.3760/cma.j.issn.1007-5232.2011.04.010
Authors:KONG De-run  ZHANG Lei  ZHANG Chao  FU Zhong-qian  HAO Jia-hu  HE Bing-bing  SUN Bin  XIE Yue  LI Pan  XU Jian-ming
Abstract:
Keywords:Esophageal and gastric varicesManometryHypertension  portal