首页 | 本学科首页   官方微博 | 高级检索  
     


Intraoperative Subareolar Injection of 99mTc-Labeled Sulfur Colloid Results in Consistent Sentinel Lymph Node Identification
Authors:Theresa?G.?Zogakis,Robert?E.?Wetherille,Robert?D.?Christensen,Kevin?J.?Ose,Joel?D.?Friedman,Marybeth?Colbert,Charles?A.?Svendsen,Omer?K.?Sanan,Todd?M.?Tuttle  author-information"  >  author-information__contact u-icon-before"  >  mailto:tuttl@umn.edu"   title="  tuttl@umn.edu"   itemprop="  email"   data-track="  click"   data-track-action="  Email author"   data-track-label="  "  >Email author
Affiliation:(1) John Wayne Cancer Institute, 2200 Santa Monica Boulevard, Santa Monica, California, 90404;(2) Park Nicollet Methodist Hospital, 6500 Excelsior Boulevard, St. Louis Park, Minnesota, 55426;(3) United Hospital, 333 North Smith Avenue, St. Paul, Minnesota, 55102;(4) Department of Surgery, University of Minnesota, 420 Delaware St. S.E., Minneapolis, Minnesota, 55455
Abstract:Background Preoperative parenchymal or peritumoral (PT) injection of 99mTc-labeled sulfur colloid (TcSC) is the standard method for sentinel lymph node (SLN) identification in patients with breast cancer. Limitations of this method include variable identification rates, slow transit times, and painful injections. We hypothesize that TcSC will travel to the SLN within minutes after injection into the subareolar (SA) lymphatics, thus making an intraoperative injection technique feasible.Methods One hundred twenty-two women with invasive breast cancer were enrolled onto this prospective study. Immediately after the induction of general anesthesia, patients were injected with 1 to 2 mCi of filtered TcSC in the SA location. Then, 5 mL of 1% isosulfan blue dye was injected into the PT location. The SLN or SLNs were identified as radioactive, blue, or both and removed for pathologic evaluation.Results The mean patient age was 56 years. The mean tumor size was 1.5 cm. In 86.1% of patients, a transcutaneous axillary ldquohot spotrdquo was identified by handheld gamma probe. The mean time from TcSC injection to axillary incision was 17.6 minutes. At least one SLN was identified in 99.2% of patients. The mean number of SLNs identified per patient was 1.83. The mean count of radioactive SLNs was 2715 cps. In 97.2% of patients, blue SLNs were also radioactive.Conclusions TcSC injected into the SA lymphatics rapidly drains to the SLN. The radioactive SLN is easily and quickly identified after an intraoperative SA TcSC injection. The simplicity of this method eliminates the inherent problems associated with standard PT injection.
Keywords:Breast cancer  Sentinel lymph node  Subareolar  Technetium
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号