The serological diagnosis of human clonorchiasis by time-resolved fluoroimmunoassay based on GST2-specific IgG4 detection
Authors:Jin Xu  Lexun Wang  Chuanhuan Deng  Xuchu Hu  Ran Li  Tingjin Chen  Dan Ning  Yingsong Wu  Yan Huang  Xuerong Li  Zhongdao Wu  Xinbing Yu  Yonglong Li
Institution:1. Department of Parasitology, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
2. Department of Parasitology, Zhongshan School of Medicine, Sun Yat-sen University, 74 Zhongshan 2nd Road, Guangzhou, 510080, China
3. Key Laboratory for Tropical Diseases Control, Ministry of Education, Sun Yat-sen University, Guangzhou, 510080, China
4. The Third Affiliated hospital, Sun Yat-sen University, Guangzhou, 510630, China
5. Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou, 510515, China
Abstract:Due to its delayed fluorescence of a lanthanide chelate, high accuracy and low background the broad linear range, long fluorescent life-time and large Stoke's shift of europium chelates, the time-resolved fluorescence has been developed for higher sensitive immunoassay. In this article, a simple, sensitive and specific method-time-resolved fluoroimmunoassay (TRFIA) was adopted for immunoassay of clonorchiasis, and recombinant glutathione transferases 2 of Clonorchis sinensis (rCsGST2) was used as a diagnostic antigen. To evaluate this novel assay for clinical applications, 409 serum samples were investigated. The diagnostic accuracy of the antigen was evaluated by receiver-operating characteristic (ROC) analysis. The area under the ROC curve (AUC) was 0.965, 95 % confidence interval (CI, 0.946, 0.985). To eliminate the random influence of ambient temperature, test parameters, photometric instruments and so on, the cut-off value was expressed as ratios between the fluorescence of sample and that of a well-defined negative control serum, and the deduced cut-off value was 9.3605. At the optimum cut-off criteria, the technique has a sensitivity of 95.80 %, specificity of 93.60 %. And the cross reactivity revealed that its cross reactivity with Schistosoma japonicum, round worm, hook worm, whip worm, and Toxoplasma gondii was 9.3, 8.3, 7.6, 9.8, and 5.0 %, respectively. Kappa score of agreement between TRFIA and microscopic examination of stools was 0.892, P?<?0.05. These combined results showed that our method is feasible and could be used for the clinical determination of clonorchiasis.