Cardiac stress-rest single-photon emission computed tomography with technetium 99m-labeled tetrofosmin: Influence of washout kinetics on regional myocardial uptake values of the rest study with a 1-day protocol |
| |
Authors: | Gernot Schulz Elisabeth Ostwald Hans J. Kaiser Jürgen vom Dahl Eduard Kleinhans Udalrich Buell |
| |
Affiliation: | 1. Departments of Nuclear Medicine and Internal Medicine I (Cardiology), Aachen University of Technology, Aachen, Germany
|
| |
Abstract: | Background The purpose of this study was to evaluate (1) the washout kinetics of99mTc-labeled tetrofosmin, separately for myocardium with normal and reduced perfusion, and (2) its influence on quantitative analysis in a 1-day stress-rest protocol. Methods and Results Twenty-five patients with angiographically proved coronary artery disease underwent bicycle exercise stress testing with injection of 200 MBq99mTc-labeled tetrofosmin and first single-photon emission computed tomographic (SPECT) imaging 40 minutes after injection. A second SPECT was acquired 2.3±0.4 hours after the first one immediately before rest injection of 800 MBq99mTc-labeled tetrofosmin. The rest (third) SPECT was acquired 15 minutes thereafter. The relative washout fraction per time (WOFt) was calculated assuming linear washout kinetics. Thirty-three regional uptake values per study were calculated, normalized to the perfusion maximum (100%) in either the postexercise SPECT and the rest SPECT, for the latter with and without correction of remaining counts from stress injection. In regions with normal perfusion, WOFt was 11.5%±3.5% per hour. In regions with markedly reduced perfusion (relative uptake <50%, WOFt was 8.3%±9.9% per hour. The highest variation of the relative uptake values between rest SPECT with and without correction of remaining counts from stress injection was 5.4%±3.5% in regions with stress-induced ischemia. Conclusion To use a 1-day protocol with a stress-rest radioactivity ratio of 1∶4 and an interval of more than 2 hours between the examinations, a correction for remaining counts from stress injection seems not to be necessary for the quantitative analysis of rest SPECT. |
| |
Keywords: | technetium 99m-labeled tetrofosmin emission computed tomography myocardial scintigraphy coronary artery disease washout kinetics |
本文献已被 ScienceDirect SpringerLink 等数据库收录! |