摘    要:
目的 通过4DCT(four-dimensional CT)动态评估咽鼓管功能障碍(Eustachian tube dysfuction,ETD)患者Valsava动作时的咽鼓管(Eustachian tube,ET)功能.方法 2018年11月~2019年3月期间就诊于首都医科大学附属北京安贞医院的ETD患者15例,...

关 键 词:咽鼓管  咽鼓管功能障碍  咽鼓管测压  咽鼓管评分量表  咽鼓管球囊扩张术

Evaluation of Eustachian tube function in patients with Eustachian tube dysfunction using a four-dimensional CT scanner
ZHU Shuanzhuang,YE Mengxiao,DENG Xitang,YAN Zixu,LIANG Biying,LI Xiping. Evaluation of Eustachian tube function in patients with Eustachian tube dysfunction using a four-dimensional CT scanner[J]. Chinese Archives of Otolaryngology-Head and Neck Surgery, 2021, 28(1): 18-21
Authors:ZHU Shuanzhuang  YE Mengxiao  DENG Xitang  YAN Zixu  LIANG Biying  LI Xiping
Affiliation:(Department of Radiology,Beijing Anzhen Hospital,Capital Medical University,Beijing,100029,China;Department of Otolaryngology Head and Neck Surgery,Beijing Anzhen Hospital,Capital Medical University,Beijing,100029,China)
Abstract:
OBJECTIVE To evaluate the Eustachian tube(ET)function during Valsava maneuver in patients with Eustachian tube dysfunction(ETD)using four-dimensional CT(4DCT).METHODS Fifteen patients with ETD and fifteen healthy volunteers were admitted to Beijing Anzhen Hospital from November 2018 to March 2019.A preliminary evaluation of the ET function was performed on all subjects using TMM,ETDQ-7,and ETS-7.The 4DCT was used for dynamic scanning.Patients performed Valsava maneuver during the scanning process and the whole opening process of the ET were recorded and reconstructed at intervals of 0.1s.MPR(multi-planar reconstruction technique)was used for reconstruction by Vitrea workstation.The ET angle,length,curvature,the pretympanic diameter were measured.The site of the ET obstruction and the maximum part of the patency were determined.The t-test and correlation analysis were used to compare the function of the ET between different groups.RESULTS The full length of ET could be observed in the normal control group,and there were different degrees of obstruction in the ETD group.In the ETD group,10(93.3%)obstruction site was in the cartilaginous portion and one in the isthmus portion.The ETl and ETαin the ETD group was significantly greater than that in the control group[(44.41±2.21)mm vs(40.60±2.20)mm,P<0.01;(168.73±4.66)mm vs(162.88±5.44)mm,P<0.01].The pretympanic diameter in the ETD group was significantly shorter than that of the control group[(3.5±0.8)mm vs(5.3±1.1)mm,P<0.001].CONCLUSION The longer the ET length,the greater the ET angle,the more susceptive it is to develop ETD.4DCT dynamic scanning can accurately assess the site of ET obstruction in ETD patients,thus it can offer guidance for balloon dilatation eustachian tuboplasty.Since the radiation dose is lower than that of the general head scan,4DCT can be used as a routine examination method for ET function.
Keywords:Eustachian Tube  Eustachian tube dysfunction  Tubomanometry  Eustachian tube score scale  balloon dilatation Eustachian tuboplasty