Risk in elderly patients after stentless versus stented aortic valve surgery
Authors:Ennker Jürgen  Rosendahl Ulrich  Ennker Ina Carolin  Bauer Stefan  Florath Ines
Affiliation:Heart Institute Lahr/Baden, Lahr, Germany. ennker@heart-lahr.com
Abstract:Recent studies suggest that the hemodynamic advantage of stentless bioprostheses over the stented type improves long-term survival after aortic valve replacement, but the more complex and time-consuming implantation technique may increase the risks of operative death and postoperative complications. Between April 1996 and June 2001, 519 patients with a mean age of 76 +/- 5 years underwent aortic valve replacement using a stentless (Medtronic Freestyle, n = 277) or stented bioprosthesis (Medtronic Mosaic, n = 242). Multiple logistic regression analysis considering different patient populations revealed no increased risk of operative death, postoperative complications, or neurological impairment after implantation of a stentless bioprosthesis. Survival curves in respect of 367 patients who underwent aortic valve replacement up to September 2000 and were followed up for 3 years were not different (p = 0.98). As the patients were elderly, improved survival due to implantation of a stentless valve could not be demonstrated within this time span.