首页 | 本学科首页   官方微博 | 高级检索  
     

数字化颅底外科的解剖及影像学研究
引用本文:满都乐歌齐,刘玉光,朱树干,杨洪安,杨扬. 数字化颅底外科的解剖及影像学研究[J]. 山东大学耳鼻喉眼学报, 2013, 27(2): 60-63. DOI: 10.6040/j.issn.1673-3770.0.2013.017
作者姓名:满都乐歌齐  刘玉光  朱树干  杨洪安  杨扬
作者单位:山东大学齐鲁医院神经外科, 济南 250012
摘    要:
目的 通过对解剖学、影像学、神经导航三种测量方式精确度的对比,对数字化颅底外科手术的可行性进行量化评估。方法 取颅底标本25个,对前半规管-卵圆孔之间的距离(50侧),分别进行游标卡尺测量(解剖学测量)、影像学测量及神经导航测量。所得数据进行记录,并采用SPSS 19.0软件进行统计分析,比较三种测量方式各自的精确度。结果 ①解剖学测量的平均偏差(离均差平均值)>影像学测量数据与解剖学测量均数的平均偏差(P<0.01); ②神经导航测量的与解剖学测量均数的平均偏差>影像学测量与解剖学测量均数的平均偏差(P<0.01); ③神经导航测量的与解剖学测量均数的平均偏差略>解剖学测量的平均偏差, 但P(90%)>0.8。结论 ①影像学测量数据在评估个体解剖学特征方面的精密度,高于基于群体的解剖学测量数据;②神经导航系统在注册及应用中会出现一些偏差,影响神经导航系统的精确性;③即使不可避免地存在着误差,从统计学角度来看,神经导航测量依然无可否认地可视为与解剖学测量为等效(把握度高达90%)。

关 键 词:神经导航  颅底外科  测量方式  
收稿时间:2013-01-11

Digitalized skullbase surgery: an anatomical and medical imageology study
Mandulegeqi,LIU Yu-guang,ZHU Shu-gan,YANG Hong-an,YANG Yang. Digitalized skullbase surgery: an anatomical and medical imageology study[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2013, 27(2): 60-63. DOI: 10.6040/j.issn.1673-3770.0.2013.017
Authors:Mandulegeqi  LIU Yu-guang  ZHU Shu-gan  YANG Hong-an  YANG Yang
Affiliation:Department of Neurosurgery, Qilu Hospital of Shandong University, Jinan 250012, China
Abstract:
Objective To quantitatively evaluated the feasibility of digitalized skull base surgery by comparing the corresponding accuracy of anatomical, imageology and neuronavigator based measurements. Methods Distance between the anterior semicircular canal and the oval foramen of 25 cadaver skull bases (50 sides) were measured with caliper (an anatomical measurement), CT (an imageology base measurement) and neuronavigator (a neuronavigator based measurement), respectively. The data were documented and the accuracy of three different methods of measurement was statistically analyzed with Spss19.0 software. Results ① The mean deviation of anatomical measurement was larger than that of the imageology based measurement from the corresponding mean of anatomical measurement(P<0.01); ② The mean deviation of the neuronavigator based measurement was larger than that of the imageology based measurement from the mean of anatomical measurement (P<0.01); ③ The mean deviation of the neuronavigator based measurement from the mean of anatomical measurement was a little bit larger than that of the anatomical measurement, whereas the P value (90%) was larger than 0.8. Conclusion ① The data from imageology based measurement are more accurate than those from group-based anatomical measurement in evaluating individual anatomical characteristics; ② Errors occurred during registration and application will compromise the accuracy of a neuronavigator to a more or less extent; ③ Statistically equivalent accuracy is undeniable(the power of the test was as high as 90%)between the anatomical and neuronavigator based measurements, even if deviations from the latter are inevitable.
Keywords:Neuronavigator; Skull base surgery  Measurement  
本文献已被 万方数据 等数据库收录!
点击此处可从《山东大学耳鼻喉眼学报》浏览原始摘要信息
点击此处可从《山东大学耳鼻喉眼学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号