Ultrasound-guided infraclavicular axillary vein puncture is effective to avoid pinch-off syndrome: a long-term follow-up study
Authors:Hideki Osawa  Junichi Hasegawa  Kazuma Yamakawa  Nobuki Matsunami  Shoki Mikata  Junzo Shimizu  Yong Kook Kim  Hirotaka Morishima  Masaki Hirota  Yoshihito Souma  Ho Min Kim  Genta Sawada  Riichiro Nezu
Affiliation:1. Department of Surgery, Osaka Rosai Hospital, 1179-3, Nagasone-cho, Kita-ku, Sakai, Osaka, 591-8025, Japan
2. Department of Traumatology and Acute Critical Medicine, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
3. Department of Surgical Oncology, Medical Institute of Bioregulation, Kyushu University, Fukuoka, Fukuoka, Japan
Abstract:

Purpose

Pinch-off syndrome (POS) is a serious complication encountered during the long-term management of totally implantable access ports (TIAPs). The aim of this study was to examine the effect of ultrasound-guided infraclavicular axillary vein puncture to avoid POS in patients with long-term use of a TIAP.

Methods

This was a retrospective review of 207 consecutive TIAPs: one hundred devices implanted using an anatomical landmark technique were used as historical controls (Landmark group), while 107 devices were implanted using an ultrasound (US)-guided puncture method (US group). The pinch-off grade (POG) was determined using chest X-ray findings following the definition of Hinke, and the progression of POG during the follow-up period of the Landmark and US groups was compared.

Results

Sixteen cases in the Landmark group were POG-1 and 3 were POG-2, while all cases in the US group were POG-0 at the time of venipuncture (p < 0.001). Eleven patients in the Landmark group showed some degree of progression of the POG during the follow-up period. In contrast, there were no cases showing progression of the POG in the US group (p = 0.002).

Conclusions

US-guided infraclavicular axillary vein puncture was found to effectively make it possible to avoid POS for the long-term management of TIAPs, as well as at the time of implantation.