首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of the Load at Fracture of Turkom-Cera to Procera AllCeram and In-Ceram All-Ceramic Restorations
Authors:Bandar M. A. AL-Makramani,BDS,HDD,MDSc,,Abdul A. A. Razak,BDS,MSc,PhD,,&   Mohamed I. Abu-Hassan,BDS,MDSc,PhD
Affiliation: Postgraduate student, Department of Conservative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia;Head, Department of Conservative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia; Dean, Department of Restorative Dentistry, Faculty of Dentistry, Universiti Teknologi MARA, Shah Alam, Malaysia
Abstract:Purpose: This study investigated the occlusal fracture resistance of Turkom-Cera-fused alumina compared to Procera AllCeram and In-Ceram all-ceramic restorations.
Materials and Methods: Six master dies were duplicated from the prepared maxillary first premolar tooth using nonprecious metal alloy (Wiron 99). Ten copings of 0.6 mm thickness were fabricated from each type of ceramic, for a total of thirty copings. Two master dies were used for each group, and each of them was used to lute five copings. All groups were cemented with resin luting cement Panavia F according to manufacturer's instructions and received a static load of 5 kg during cementation. After 24 hours of distilled water storage at 37°C, the copings were vertically compressed using a universal testing machine at a crosshead speed of 1 mm/min.
Results: The results of the present study showed the following mean loads at fracture: Turkom-Cera (2184 ± 164 N), In-Ceram (2042 ± 200 N), and Procera AllCeram (1954 ± 211 N). ANOVA and Scheffe's post hoc test showed that the mean load at fracture of Turkom-Cera was significantly different from Procera AllCeram ( p < 0.05). Scheffe's post hoc test showed no significant difference between the mean load at fracture of Turkom-Cera and In-Ceram or between the mean load at fracture of In-Ceram and Procera AllCeram.
Conclusion: Because Turkom-Cera demonstrated equal to or higher loads at fracture than currently accepted all-ceramic materials, it would seem to be acceptable for fabrication of anterior and posterior ceramic crowns.
Keywords:Turkom-Cera    load at fracture    modes of fracture