首页 | 本学科首页   官方微博 | 高级检索  
检索        

携ICAM-1单抗超声造影剂体外评估兔腹主动脉内皮损伤实验研究
引用本文:李馨,高云华,谭开彬,刘平,卞爱娜.携ICAM-1单抗超声造影剂体外评估兔腹主动脉内皮损伤实验研究[J].中国医学影像技术,2004,20(10):1501-1502.
作者姓名:李馨  高云华  谭开彬  刘平  卞爱娜
作者单位:第三军医大学新桥医院超声科,重庆,400037
摘    要:目的探讨携ICAM-1 单抗的超声造影剂评价血管内皮损伤的可行性及其价值.方法 FITC标记自制含氟碳声振白蛋白造影剂及携ICAM-1 单抗的靶向超声造影剂.新西兰大白兔8只,高脂饮食建立内皮损伤动物模型后,取兔腹主动脉做冰冻病理切片,随机分两组,分别滴加非靶向造影剂、靶向造影剂,比较两种微泡内皮分布情况及相应荧光染色度的差异.结果靶向造影剂组内皮黏附微泡明显增多,荧光染色较强.结论携ICAM-1 单抗的造影剂微泡可靶向黏附于损伤内皮,据此可评价早期内皮损伤.

关 键 词:靶向造影剂  腹主动脉  内皮功能  动物  实验
文章编号:1003-3289(2004)10-1501-02
修稿时间:2004年5月9日

Detecting endothelial dysfunction of abdominal aorta in rabbits in vitro with microbubbles conjugated anti-ICAM-1
LI Xin,GAO Yun-hu,TAN Kai-bin,LIU Ping and BIAN Ai-na.Detecting endothelial dysfunction of abdominal aorta in rabbits in vitro with microbubbles conjugated anti-ICAM-1[J].Chinese Journal of Medical Imaging Technology,2004,20(10):1501-1502.
Authors:LI Xin  GAO Yun-hu  TAN Kai-bin  LIU Ping and BIAN Ai-na
Institution:Department of Ultrasound, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;Department of Ultrasound, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;Department of Ultrasound, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;Department of Ultrasound, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China;Department of Ultrasound, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China
Abstract:Objective To discuss the value and feasibility of targeted microbubbles conjugated to anti-ICAM-1 in monitoring endothelial dysfunction. Methods Fluorescein isothiocyanate (FITC) was mixed with self-made microbubbles and anti-ICAM-1 conjugated microbubbles respectively. Eight New Zealand rabbits were fed with cholesterol diet to create the animal model of endothelial dysfunction. Aorta was dissected and tissue slides were prepared. Two kinds of microbubbles were added to the glass slide and the behaviors of targeted and nontargeted microbubbles were observed through fluoroscope. Results Microbubbels retained within the endothelium were much more for anti-ICAM-1 containing than for standard microbubbles. The fluorescent signal from the endothelium for targeted microbubbles was much higher than that of nontargeted ones. Conclusion Microbubbles conjugated to anti-ICAM-1 have been shown to bind to activated endothelial cells. It can be used to assess early endothelial damage.
Keywords:Targeted microbubbles  Abdominal aorta  Endothelial function  Animals  laboratory
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号