首页 | 本学科首页   官方微博 | 高级检索  
     


Hepatic artery stenosis following liver transplantation: significance of the tardus parvus waveform and the role of microbubble contrast media in the detection of a focal stenosis
Authors:Sidhu P S  Ellis S M  Karani J B  Ryan S M
Affiliation:Department of Diagnostic Radiology, King's College Hospital, London, UK. paulsidhu@compuserve.com
Abstract:
PURPOSE: To evaluate the role of microbubble ultrasound contrast media in detecting stenosis of the post-liver transplant extrahepatic hepatic artery (HA) in the presence of the tardus parvus spectral Doppler waveform of the intrahepatic HA. MATERIALS AND METHODS: All post-liver transplant patients with a prolonged systolic acceleration time (SAT>0.08s) and/or a reduced resistant index (RI<0.50) of the HA (the tardus parvus waveform) on colour Doppler ultrasound (CDUS), were assessed with microbubble contrast medium for a focal arterial stenosis. Following microbubble contrast-enhanced CDUS, patients underwent arteriography or follow-up CDUS. RESULTS: A total of 2038 examinations were performed in 529 liver transplant recipients; 16 (3.02%) tardus parvus waveforms were identified. The median SAT of the intrahepatic HA was 0.18s (range 0.11-0.38s) and the RI 0.47 (range 0.22-0.58). No extrahepatic elevated peak systolic velocity (PSV), defined as above 1.00m/s, was detected on the baseline examinations. Following the administration of microbubble contrast, medium, PSV in the extrahepatic HA was elevated in 14 of 16 patients, (median=2.15m/s, range=1.44-3.10m/s); flow was not identified in two patients. Arteriography was performed in 10 patients and confirmed stenosis in eight (median grade of stenosis 93%, range 60-99%) and occlusion in two. The measured median PSV at contrast-enhanced CDUS in the stenosis group was 2.03m/sec (range 1.44-2.71m/sec). Repeat CDUS in six patients not undergoing arteriography showed resolution in four; one underwent re-transplantation before arteriography and one patient maintains a tardus parvus waveform. In transplant recipients undergoing arteriography during the study period (n=55), no hepatic artery stenosis without a tardus parvus waveform was seen. CONCLUSION: The tardus parvus waveform pattern is an excellent screening test for the presence of post-liver transplantation hepatic artery stenosis. There is only a limited role for microbubble ultrasound contrast agent in the presence of a tardus parvus waveform. It could be used following equivocal colour Doppler ultrasound, but arteriography will still be necessary.
Keywords:Liver transplantation, hepatic arteries, stenosis or obstruction, hepatic arteries, transluminal angioplasty   ultrasound (US), contrast media   ultrasound (US), Doppler studies
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号