首页 | 本学科首页   官方微博 | 高级检索  
     


Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures
Authors:Stephen P. Povoski  Ismet Sarikaya  William C. White  Steven G. Marsh  Nathan C. Hall  George H. Hinkle  Edward W. MartinJr.  Michael V. Knopp
Affiliation:(1) Division of Surgical Oncology, Department of Surgery, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute and Comprehensive Cancer Center, The Ohio State University, Columbus, OH 43210, USA;(2) Division of Nuclear Medicine, Department of Radiology, The Ohio State University, Columbus, OH 43210, USA;(3) The Office of Environmental Health and Safety, The Ohio State University, Columbus, OH 43212, USA;(4) College of Pharmacy, The Ohio State University, Columbus, OH 43210, USA;(5) N-924 Doan Hall, 410 West 10th Avenue, Columbus, Ohio 43210, USA
Abstract:
Purpose  The purpose of the current study was to comprehensively evaluate occupational radiation exposure to all intraoperative and perioperative personnel involved in radioguided surgical procedures utilizing 18F-fluorodeoxyglucose (18F-FDG). Methods  Radiation exposure to surgeon, anesthetist, scrub technologist, circulating nurse, preoperative nurse, and postoperative nurse, using aluminum oxide dosimeters read by optically stimulated luminescence technology, was evaluated during ten actual radioguided surgical procedures involving administration of 18F-FDG. Results  Mean patient dosage of 18F-FDG was 699 ± 181 MBq (range 451–984). Mean time from 18F-FDG injection to initial exposure of personnel to the patient was shortest for the preoperative nurse (75 ± 63 min, range 0–182) followed by the circulating nurse, anesthetist, scrub technologist, surgeon, and postoperative nurse. Mean total time of exposure of the personnel to the patient was longest for the anesthetist (250 ± 128 min, range 69–492) followed by the circulating nurse, scrub technologist, surgeon, postoperative nurse, and preoperative nurse. Largest deep dose equivalent per case was received by the surgeon (164 ± 135 μSv, range 10–580) followed by the anesthetist, scrub technologist, postoperative nurse, circulating nurse, and preoperative nurse. Largest deep dose equivalent per hour of exposure was received by the preoperative nurse (83 ± 134 μSv/h, range 0–400) followed by the surgeon, anesthetist, postoperative nurse, scrub technologist, and circulating nurse. Conclusion  On a per case basis, occupational radiation exposure to intraoperative and perioperative personnel involved in 18F-FDG radioguided surgical procedures is relatively small. Development of guidelines for monitoring occupational radiation exposure in 18F-FDG cases will provide reassurance and afford a safe work environment for such personnel.
Keywords:18F-fluorodeoxyglucose  Radiation protection  Dosimetry  Operating rooms  Perioperative nursing
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏