首页 | 本学科首页   官方微博 | 高级检索  
     


Validity,reliability and ease of use in the field of five rapid tests for the diagnosis of Plasmodium falciparum malaria in Uganda
Authors:Guthmann J P  Ruiz A  Priotto G  Kiguli James  Bonte L  Legros D
Affiliation:Epicentre, 4 rue Saint Sabin, 75011 Paris, France. jguthmann@epicentre.msf.org
Abstract:
A study was conducted to measure the overall performance of several rapid diagnostic tests for Plasmodium falciparum infection, in order to select the most appropriate test to be used in the field. A total of 742 patients attending the out-patient department of Mbarara Hospital with a clinical suspicion of malaria were included in the study. For each patient, a thick/thin film and 5 rapid tests based on the detection of histidine-rich protein II (HRP-II) (Paracheck Pf dipstick and device, ParaHIT f, Malaria Rapid and BIO P.F.) were performed. Outcomes were validity, inter-reader reliability and 'ease of use in the field', measured by both the general characteristics of the test and by the opinion of the readers. About half (57%) of the patients were positive for P. falciparum. The Paracheck Pf (dipstick and device) was considered as the most appropriate for the use in the field, being sensitive (97%), moderately specific (88%), reliable (kappa coefficient = 0.97), easy to use and cheap (about US$ 0.5/test). The ParaHIT f represented a good alternative.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏